Balloon-Expandable Transcatheter Aortic Valve Implantation for LVAD-Associated Native Aortic Insufficiency: A Single-Center Experience.
Bilge Duran Karaduman, Telat Keleş, Özlem Özcan Çelebi, Sinan Sabit Kocabeyoğlu, Abdulkadir Yılmaz, Mustafa Akdi, Ümit Kervan
Department of Cardiology, Ankara Bilkent City Hospital, 06800 Ankara, Türkiye. · Department of Cardiovascular Surgery, Ankara Bilkent City Hospital, 06800 Ankara, Türkiye.
Key points
From the paper's conclusion- In anatomically complex LVAD patients, an anatomy-driven balloon-expandable TAVI strategy achieved elimination of clinically significant AI with zero procedural mortality. In our interpretation, mortality reflected the advanced stage of heart failure at the time of intervention rather than acute device-related failure.
Abstract
BACKGROUND: Aortic insufficiency (AI) during long-term left ventricular assist device (LVAD) support creates a maladaptive recirculatory loop that impairs forward flow, increases left ventricular filling pressures, leading to progressive congestion, and accelerates right ventricular dysfunction. Surgical correction carries high risk, making transcatheter aortic valve implantation (TAVI) an alternative strategy, although outcomes are challenged by complex annular geometry and the absence of calcific anchoring. METHODS: We performed a retrospective single-center analysis of consecutive LVAD-supported patients undergoing TAVI for native AI. Annular sizing was area-based with a predefined oversizing strategy of approximately 15-30%, adjusted to annular geometry. Balloon-expandable valves were implanted using controlled deployment under rapid pacing and temporary LVAD flow reduction. Outcomes were assessed according to VARC-3 definitions. RESULTS: Fourteen patients underwent TAVI. The cohort demonstrated high anatomical complexity, including annular eccentricity (median 0.21 [IQR 0.19-0.23]), horizontal aorta (42.9%), and flared left ventricular outflow tract (LVOT) morphology (50%). Median annular area was 528 mm2 (IQR 487-574), with area-derived diameter 25.9 mm (IQR 24.9-27.0). Mean oversizing was 21.9% (median 20.0%; range 15.1-30.3%). Technical and VARC-3 device success were achieved in 71.4%. Second valve implantation occurred in 28.6%. Procedural mortality was 0%. In-hospital mortality (21.4%) was related to low cardiac output and multi-organ dysfunction rather than device failure. No survivor had moderate or greater residual AI at discharge. CONCLUSIONS: In anatomically complex LVAD patients, an anatomy-driven balloon-expandable TAVI strategy achieved elimination of clinically significant AI with zero procedural mortality. In our interpretation, mortality reflected the advanced stage of heart failure at the time of intervention rather than acute device-related failure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Self-Expanding Supra-Annular Transcatheter Valve for Pure Native Aortic Insufficiency: Rationale and Technique.JACC. Case reports · 2026
- Outcomes of Transcatheter Aortic Valve Replacement for Aortic Regurgitation in LVAD Patients: The JENA-VAD Study.Journal of the American College of Cardiology · 2026
- Early Multicenter Outcomes of Dedicated Transcatheter Aortic Valve Replacement for Left Ventricular Assist Device-Associated Pure Aortic Regurgitation.Artificial organs · 2026
- Efficacy and Safety of Routine Postdilation in Balloon-Expandable Transcatheter Aortic Valve Implantation Platform: The DUOTAP Randomized Clinical Trial.JAMA cardiology · 2026
- Left ventricular remodeling and outcome after transcatheter aortic valve implantation in patients with small aortic annulusEuropean Heart Journal · 2026
- Self-expanding intraannular transcatheter heart valve in tapered LVOT morphology - impact on deployment precision and periprocedural aortic prosthesis migration.Clinical research in cardiology : official journal of the German Cardiac Society · 2026