InfrastructuresOpen accessStructural engineering

Structural Behavior of Pre-Loaded Fire-Damaged RC Columns Rehabilitated with UHPC

Mohanad Wisam Mousa, Sarmad Shafeeq Abdulqader, Ahlam Sader Mohammed

University of Technology - Iraq

Key points

From the paper's conclusion
  • This study presents an experimental investigation into the rehabilitation of fire-damaged reinforced concrete (RC) columns using Ultra-High-Performance Concrete (UHPC) under an eccentric load of (e = 45 mm).

Abstract

This study presents an experimental investigation into the rehabilitation of fire-damaged reinforced concrete (RC) columns using Ultra-High-Performance Concrete (UHPC) under an eccentric load of (e = 45 mm). The experimental program comprised nine small-scale RC column specimens, which were divided into two groups based on exposure temperatures of 500 °C and 700 °C, applied using a specially designed furnace. A control column that was not exposed to fire was also tested for comparison. The study included two fire exposure durations: 60 and 120 min. During the heating phase, the columns were subjected to a pre-applied axial load equal to 50% of their ultimate capacity (Pu). After sustaining fire-induced damage, the columns were rehabilitated using UHPC jacketing. The experimental results revealed a reduction in the ultimate load-carrying capacity of the RC columns with increasing fire temperature and exposure duration. Specifically, the load capacity decreased by 22.68% and 33.89% when exposed to 500 °C for 60 and 120 min, respectively, and by 42.02% and 49.02% when exposed to 700 °C for 60 and 120 min, respectively, compared with the control column. However, strengthening the fire-damaged columns with UHPC significantly enhanced their structural performance, resulting in an increase in ultimate load capacity ranging from 81.88% to 157.14% compared with their corresponding fire-damaged unstrengthened specimens. Based on the experimental findings, the load lateral displacement response at mid-height, load–axial deformation curves, failure modes, ductility, and stiffness characteristics of the columns were analysed. The study concludes that the use of UHPC in rehabilitating fire-exposed columns substantially improves most of these structural properties.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Structural Behavior of Pre-Loaded Fire-Damaged RC Columns Rehabilitated with UHPC — Science Skim