Evaluating the Convective Coefficient for Cylindrical Radiation Thermometers in the Conditions of Interest for Outdoor Thermal Comfort: A CFD Analysis
Manfredo Guilizzoni, Roberta Caruana, Luca Marocco, Adriana Angelotti
Key points
From the paper's conclusion- Overall, these findings support the use of standard forced convection correlations for estimating the convective coefficient of cylindrical radiation thermometers under typical outdoor conditions, simplifying the determination of the mean radiant temperature and supporting the assessment of passive heat mitigation strategies in urban environments.
Abstract
Slender cylindrical radiation thermometers have been proposed as an alternative to conventional globe thermometers for outdoor thermal comfort assessment, as they better represent pedestrians’ exposure to solar radiation. Nevertheless, determining the mean radiant temperature from their measurements requires an accurate estimate of the convective heat transfer coefficient. For these devices, forced and natural convection are governed by different characteristic lengths, namely the cylinder diameter, D, and height, H, respectively. Based on measurements from a preliminary outdoor experimental campaign with a cylindrical radiation thermometer, the Richardson number calculated using these two characteristic lengths, RiHD, was found to be of the order of unity, initially suggesting the possible occurrence of mixed convection. However, suitable mixed convection correlations for this configuration are unavailable. Therefore, Computational Fluid Dynamics simulations were conducted to determine the convective heat transfer coefficient under different conditions. The results showed that, in 23 out of 25 investigated cases, the convective coefficients obtained from the numerical simulations fell within the range of established forced convection correlations or exceeded its upper limit by less than 1%. Larger deviations, of 5.2% and 9.2%, occurred only under combinations of very low wind speeds and large air-cylinder temperature differences, unlikely to occur in typical outdoor thermal comfort applications. Furthermore, the conventional Richardson number thresholds were found to be unsuitable for interpreting RiHD, whereas the Richardson number calculated using the cylinder diameter for both natural and forced convection, RiD, provided indications consistent with the identified convection regimes. Overall, these findings support the use of standard forced convection correlations for estimating the convective coefficient of cylindrical radiation thermometers under typical outdoor conditions, simplifying the determination of the mean radiant temperature and supporting the assessment of passive heat mitigation strategies in urban environments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mixed convection and radiative heat transfer analysis of a bladed cylindrical receiverApplied Thermal Engineering · 2026
- Computational Fluid Dynamics-Based Quantitative Assessment and Performance Optimization of Thermal Comfort in Hyper-Arid Climate Office BuildingsSustainability · 2025
- Mixed convection in a square cavity filled with a non-Newtonian nanofluidEPJ Web of Conferences · 2026
- Mean radiant temperature in outdoor urban environments: From radiative physics to data-driven and hybrid modelling frameworksBuilding and Environment · 2026
- Effect of concave and convex side-wall curvature on natural convective heat transfer in trapezoidal enclosuresInternational Journal of Energy Studies · 2026
- CFD Assessment of Thermal Comfort and Heating Demand in Courtrooms Under Envelope Retrofit ScenariosThermo · 2026