Experimental Evaluation of RC Structures with Brick Infills for Vertical Forest Adaptation in Seismic Regions
Theodoros Rousakis, Vachan Vanian, Martha Lappa, Adamantis G. Zapris, Ioannis P. Xynopoulos, Maristella Ε. Voutetaki, Stefanos Kellis, George M. Sapidis,
Democritus University of Thrace
Key points
From the paper's conclusion- A three-dimensional single-story RC frame with brick infills, representative of pre-Eurocode Mediterranean construction (non-ductile detailing, inadequate transverse reinforcement), was tested at serviceability limit states (SLSs) (Phase A) using a dynamic pushover approach with the 1978 Thessaloniki earthquake record, progressively scaled from EQ0.1g to EQ1.1g within the GREENERGY vertical forest
Abstract
Existing Mediterranean reinforced concrete buildings with masonry infills exhibit critical seismic vulnerabilities, yet real-time damage detection capabilities remain limited. This study validates a novel dense piezoelectric transducer (PZT) network concept for early damage detection in deficient RC structures under progressive seismic loading. A three-dimensional single-story RC frame with brick infills, representative of pre-Eurocode Mediterranean construction (non-ductile detailing, inadequate transverse reinforcement), was tested at serviceability limit states (SLSs) (Phase A) using a dynamic pushover approach with the 1978 Thessaloniki earthquake record, progressively scaled from EQ0.1g to EQ1.1g within the GREENERGY vertical forest renovation project. The specimen featured 48 PZTs using electromechanical impedance (EMI) methodology, 12 accelerometers, 8 displacement sensors, and 20 strain gauges. Progressive infill deterioration initiated at EQ0.5g while steel reinforcement remained elastic (max 2350 μstrain < 2890 μstrain yield). Maximum inter-story drift reached 11.37‰ with negligible residual drift (0.204‰). The PZT network, analyzed through Root Mean Square Deviation (RMSD), successfully detected internal cracking and infill-frame debonding before visible manifestation, validating its early warning capability. Floor acceleration amplification increased from 1.26 to 1.57, quantifying structural stiffness degradation. These SLS results provide critical baseline data enabling the Phase B implementation of sustainable vertical forest retrofitting strategies for aging Mediterranean building stock.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Physics and Vision Framework for Rapid Post-Earthquake Assessment of RC Double-Column PiersBuildings · 2026
- Assessment of Seismic Performance and Structural Health Monitoring of a Retrofitted Reinforced Concrete Structure with Polyurethane-Based Interventions and Vertical Greenery SystemsPolymers · 2025
- Seismic Fragility of Urban Rail Transport RC Solid Piers Considering Multiparameter EffectsBuildings · 2026
- Impact of Earthquake Hazard on Various Structures-A Case Study in Myanmar.TheScientificWorldJournal · 2026
- An Integrated, Experimentally Validated Micro-to-Macro Nonlinear Modeling Method for AAC Masonry-Infilled RC Frame Buildings with Seismic Vulnerability Reduction StrategyBuildings · 2026
- Development of a New Analytical Approach for Earthquake‐Induced Hydrodynamic Forces of Elevated Pile‐Cap Foundations Submerged in WaterEarthquake Engineering & Structural Dynamics · 2026