Assessment of Seismic Performance and Structural Health Monitoring of a Retrofitted Reinforced Concrete Structure with Polyurethane-Based Interventions and Vertical Greenery Systems
Theodoros Rousakis, Vachan Vanian, Martha Lappa, Adamantis G. Zapris, Ioannis P. Xynopoulos, Maristella Ε. Voutetaki, Stefanos Kellis, George M. Sapidis,
Democritus University of Thrace
Key points
From the paper's conclusion- This study examines Phase B of the GREENERGY project focusing on the seismic performance and structural health monitoring of a renovated single-story RC frame with brick masonry infills that received significant strategic structural interventions.
Abstract
This study examines Phase B of the GREENERGY project focusing on the seismic performance and structural health monitoring of a renovated single-story RC frame with brick masonry infills that received significant strategic structural interventions. The columns were confined with basalt fiber ropes (FR, 4 mm thickness, two layers) in critical regions, the vertical interfaces between infill and concrete were filled with polyurethane PM forming PUFJ (PolyUrethane Flexible Joints), and glass fiber mesh embedded in polyurethane PS was applied as FRPU (Fiber Reinforced PolyUrethane) jacket on the infills. Further, greenery renovations included the attachment of five double-stack concrete planters (each weighing 153 kg) with different support-anchoring configurations and of eight steel frame constructions (40 kg/m2) simulating vertical living walls (VLW) with eight different connection methods. The specimen was subjected to progressively increasing earthquake excitation based on the Thessaloniki 1978 earthquake record with peak ground acceleration ranging from EQ0.07 g to EQ1.40 g. Comprehensive instrumentation included twelve accelerometers, eight draw wire sensors, twenty-two strain gauges, and a network of sixty-one PZTs utilizing the EMI (Electromechanical Impedance) technique. Results demonstrated that the structure sustained extremely high displacement drift levels of 2.62% at EQ1.40 g while maintaining structural integrity and avoiding collapse. The PUFJ and FRPU systems maintained their integrity throughout all excitations, with limited FRPU fracture only locally at extreme crushing zones of two opposite bottom bricks. Columns’ longitudinal reinforcement entered yielding and strain hardening at top and bottom critical regions provided the FR confinement. VLW frames exhibited equally remarkably resilient performance, avoiding collapse despite local anchor degradation in some investigated cases. The planter performance varied significantly, yet avoiding overturning in all cases. Steel rod anchored planter demonstrated superior performance while simply supported configurations on polyurethane pads exhibited significant rocking and base sliding displacement of ±4 cm at maximum intensity. PZT structural health monitoring (SHM) sensors successfully tracked damage progression. RMSD indices of PZT recordings provided quantifiable damage assessment. Elevated RMSD values corresponded well to visually observed local damages while lower RMSD values in columns 1 and 2 compared with columns 3 and 4 suggested that basalt rope wrapping together with PUFJ and FRPU jacketed infills in two directions could restrict concrete core disintegration more effectively. The experiments validate the advanced structural interventions and vertical forest renovations, ensuring human life protection during successive extreme EQ excitations of deficient existing building stock.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimental Investigation of Retrofitting and Structural Health Monitoring of Reinforced Concrete Beam–Column Joints Under Seismic LoadingApplied Sciences · 2026
- Retrofitting damaged subway station columns with CFRP grid-reinforced ECC jackets for improved seismic performanceEngineering Structures · 2025
- A multi-phase shaking table dataset of reinforced concrete frames retrofitted with a timber–aluminium exoskeletonScientific Data · 2026
- Energy and Seismic Affordable Renovation Solutions: Methods and Outcomes of the e-SAFE ProjectBuildings · 2026
- An Integrated, Experimentally Validated Micro-to-Macro Nonlinear Modeling Method for AAC Masonry-Infilled RC Frame Buildings with Seismic Vulnerability Reduction StrategyBuildings · 2026
- Multi-Objective Circular Economy Optimisation for Seismic Retrofit of Reinforced Concrete Shear WallsBuildings · 2026