Waste Heat Recovery Limits for Energy-Efficient Climate Control in Mobile Working Machines
Karol Durczak, Jan Bocianowski, Magdalena Lemecha, Zdzisław Kaliniewicz, Piotr Markowski, María Jesús Romero-Lara
Key points
From the paper's conclusion- This study re-analyses 64 previously published operating points of a renewable air-cooling unit comprising a desiccant wheel and a dew-point indirect evaporative cooler.
Abstract
Low-grade waste heat may potentially support desiccant regeneration in the climate-control systems of mobile working machines, if both sufficient source temperature and usable thermal power are available. This study re-analyses 64 previously published operating points of a renewable air-cooling unit comprising a desiccant wheel and a dew-point indirect evaporative cooler. Measured or published air states and volumetric flows were reconciled to calculate conditional heating-coil requirements for a nominal 60 °C outlet temperature. Supplementary outlet-temperature ranges from separate experiments were transferred only to 30 cases with exactly matching published inlet settings. Nominal demand ranged from 6.30 to 23.81 kW (median 13.29 kW); the remaining 34 cases had no supplementary temperature ranges. A consistency audit found that system-level process/regeneration moisture-indicator ratios were within ±10% of unity in only 8 of 64 cases and that the reconstructed 5–7 enthalpy change exceeded conditional 5–6 heating demand in 15 cases. These comparisons identify unresolved boundary/state limitations, not proven violations of conservation. Illustrative input-perturbation calculations were reported separately from experimental uncertainty. The resulting heating demands and source-screening inequalities are necessary conditional references, not measured recovered heat, demonstrated engine integration, COP improvement or fuel savings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Wraparound Heat Exchangers and Passive Desiccant Wheels for Improving Dehumidification and Reducing Reheat: Evidence and LimitationsEnergies · 2026
- Integration of High-Temperature Heat Pumps in Industrial Nut Roasting: Psychrometric Assessment for Exhaust Waste Heat Recovery Application and Primary Energy Requirement ReductionJournal of Physics: Conference Series · 2026
- Design and simulation of a novel modular solar-regenerative solid desiccant dehumidification systemRenewable Energy · 2026
- Application of a Thermoelectric Heat Pump to a Desiccant‐Based Atmospheric Water HarvesterJournal of Thermal Science and Engineering Applications · 2026
- Thermoelectric Condensate Production and a Feasibility Assessment of Its Reuse for Indoor Plant IrrigationSustainability · 2026
- Numerical simulation of transformer low-grade waste heat recovery system based on thermoelectric generationJournal of Physics: Conference Series · 2026