Trigeneration for Italian University Campuses: A Thematic Review
Fabio Cardona, Vamsi Sagiraju
Key points
From the paper's conclusion- This thematic review assesses which claims about trigeneration (combined cooling, heating, and power) at Italian university campuses are supported by published institutional, climatic, and plant-level evidence, and which remain hypothetical.
Abstract
University campuses are major energy consumers, necessitating innovative strategies to reduce grid load while protecting the environment. In Italy, climatic conditions vary substantially across the north, central, and southern regions. This thematic review assesses which claims about trigeneration (combined cooling, heating, and power) at Italian university campuses are supported by published institutional, climatic, and plant-level evidence, and which remain hypothetical. The evidence is analysed in three interconnected stages: (i) 2024 institutional electricity data and enrolment for five universities, compared using explicit accounting boundaries and harmonised to a lower-bound basis; (ii) heating and cooling degree days for their respective cities in 2023 and 2024, calculated from hourly temperature data and used solely as indicators of outdoor temperature exposure; and (iii) documented cogeneration and trigeneration installations at eight university sites, including the characteristics of eight prime-mover and system types. Reported electricity consumption in 2024 ranges from 25 to 47 GWh (average power 2.9 to 5.4 MW) on non-comparable boundaries; the four campuses with total or lower-bound figures fall between 36.6 and 47.2 GWh (4.2 to 5.4 MW). All five cities are heating-dominated; cooling degree days account for about 30% of total degree days in Rome and Naples, compared with 10% to 17% in Milan, Turin, and Padua. On-site generation accounts for 27 to 35 per cent of campus power where data are available. The most thoroughly documented options are reciprocating engines and microturbines, while the remaining technologies are primarily experimental. Because cost, hourly load, or emission statistics are unavailable, the technology assessment is a conditional, qualitative screening rather than an optimisation, and conclusions about the suitability of individual campuses are considered hypotheses.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Análisis de Impacto al Calentamiento Atmosférico generado por Sistemas de Climatización en Edificios de una Institución Educativa: Consumo eléctrico y uso de gases RefrigerantesTECTZAPIC Revista Académico-Científica · 2026
- Energy Conversion Efficiency and Carbon Intensity of EU Energy SystemsEnergies · 2026
- Integrated Water, Energy, and Carbon Footprint Analysis of Higher Education Campuses in Arid Environments: Sustainability InsightsSustainability · 2026
- Warmer Winters and Hotter Summers Reshape Residential Heating and Cooling Energy Demand Across the EU-27Sustainability · 2026
- From servers to services: modeling data centers as heat-active urban energy prosumersApplied Energy · 2025
- Sensitivity of Heating Energy Demand to Indoor Temperature, Effective Air-Change Rate, and Climate: A TRNSYS Case Study Supporting Sustainable Operation of a Multi-Apartment BuildingSustainability · 2026