Enhanced Low-Order Harmonic Suppression by Odd-Harmonic Repetitive Control with Reduced Passive Damping for Shipboard Grid-Supply Inverters
Zhengkai Lv, Ning Wang, Haojun Wu
Key points
From the paper's conclusion- The results support a bounded near-even-resonance mechanism and the measured controller–resistor configurations; capacitor-branch loss reduction is not equated with whole-converter efficiency.
Abstract
Shipboard grid-supply inverters operating at low switching frequencies must suppress rectifier-load harmonics while limiting LC resonance and capacitor-branch loss. This study separates the magnitude, harmonic-parity and phase roles in a fixed 50 Hz LC-filtered inverter. An internal-model comparison establishes an even-centered detuning interval in which odd-harmonic repetitive control has lower magnitude than conventional repetitive control. A gain compensator allocates fifth/seventh-harmonic gain and LC-band attenuation, while an all-pass section provides an independent phase variable. A fully specified numerical reference permits reconstruction of complete closed-loop poles, gain-12/gain-15 responses and parameter checks. Independently tuned multi-resonant and phase-lead repetitive benchmarks expose trade-offs between selected-harmonic rejection and resonance-band sensitivity. Targeted 480/530 Hz detuning and transformer/load-admittance scenarios identify limits to uniform performance advantages. These calculations are distinguished from prototype records acquired with a different baseline implementation. The proposed-controller records at 0.25 ohm report phase-voltage THDs of 2.67, 2.57 and 2.54 percent. Same-resistance hardware records cover four component-comparison configurations and two prior-method comparators, with tuning and measurement boundaries retained. Transient performance is not uniformly superior. The results support a bounded near-even-resonance mechanism and the measured controller–resistor configurations; capacitor-branch loss reduction is not equated with whole-converter efficiency.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- OHRC-ESO-ADECC for Harmonic Suppression in LCL–LC Grid-Tied Inverters Under Distorted Grid VoltagesElectronics · 2026
- Hybrid Active Damping for LCL-Filtered Inverters Under Weak-Grid Conditions Using Dual-Current Feedback and Capacitor-Voltage FeedforwardElectricity · 2026
- Active damping and harmonic suppression strategy of LCL Grid-tied inverters based on single inverter-side inductor current feedback considering sampling delayJournal of Physics: Conference Series · 2026
- Realisation-Aware Fractional Shaping for Robust Current Control of a Frequency-Controlled Parallel-Resonant InverterFractal and Fractional · 2026
- Symmetry-Based Simulation of a Dual Inverter Under Different Load ConditionsSymmetry · 2026
- Passive–Active Co-Design for Robust LCL-Filtered Grid-Connected Photovoltaic InvertersEnergies · 2026