OHRC-ESO-ADECC for Harmonic Suppression in LCL–LC Grid-Tied Inverters Under Distorted Grid Voltages
Zhengkai Lv, Ning Wang, Haojun Wu
Key points
From the paper's conclusion- LCL–LC filters attenuate switching-frequency harmonics, but distorted grid voltages still induce low-order harmonic currents.
Abstract
LCL–LC filters attenuate switching-frequency harmonics, but distorted grid voltages still induce low-order harmonic currents. Combining repetitive compensation with a higher-order filter also requires an implementable inverse and a stability analysis that retains the controller’s internal dynamics. This paper develops an odd-harmonic repetitive control (OHRC) and extended state observer (ESO)-based active disturbance estimation–compensation controller (OHRC-ESO-ADECC) for this problem. Its contribution is a discrete realization in which the predictor, correction, and voltage-command sequence defines the internal compensation channel. Half-period memory permits causal finite approximation of its nonminimum-phase inverse, while complete-mode analysis relates inverse length to the limits of closed-loop decay. At 5 kHz, averaged-model comparisons use the same harmonic-admittance objective, stability test, and noise budget. At the original benchmark budget, the selected five-term inverse reduces the objective from 19.071 to 12.550 mA/V relative to the selected phase-lead compensator, a 34.2% reduction, with higher calculated noise gain. Tighter budgets can instead favor phase lead. Hardware records compare four controller architectures during grid-voltage and current-reference steps; recovery rankings depend on the evaluation tolerance. The results provide a constraint-based selection procedure that balances harmonic-current suppression, recovery, noise amplification, and implementation cost rather than an unconditional preference for a longer inverse.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hybrid Active Damping for LCL-Filtered Inverters Under Weak-Grid Conditions Using Dual-Current Feedback and Capacitor-Voltage FeedforwardElectricity · 2026
- Enhanced Low-Order Harmonic Suppression by Odd-Harmonic Repetitive Control with Reduced Passive Damping for Shipboard Grid-Supply InvertersEnergies · 2026
- Active damping and harmonic suppression strategy of LCL Grid-tied inverters based on single inverter-side inductor current feedback considering sampling delayJournal of Physics: Conference Series · 2026
- Coordinated Design of Extended-State Observer-Based SOGI-PLL and Optimized Voltage Feedforward for Enhanced Disturbance RejectionMathematics · 2026
- Output Voltage Control of a Half-Bridge LLC Resonant Converter Based on Nonsingular Fast Terminal Sliding Mode Active Disturbance Rejection ControlEngineering Research Express · 2026
- An Algorithm for Switching Time Calculation in a Unipolar SPWM Grid-Connected Full-Bridge InverterAlgorithms · 2026