Electrothermal Failure Mechanism of Multi-Finger Contacts in a Disconnector Under Foundation-Induced Displacement
Jia Zhang, Bodong Chen, Kang Liu, Tiancun Wu, Hailong Wang, Luyao Wang, Miao Wen
Key points
From the paper's conclusion- Thus, total resistance can conceal local degradation, while load redistribution and current concentration increase Joule heating in remaining paths and explain burnout.
Abstract
To clarify the electrothermal failure of fixed contacts in a 363 kV three-phase five-column disconnector, field inspection, circuit-resistance tests, contact-mechanical modeling, finger-level resistance calculation, and electrothermal simulation were combined. The fault side had approximately 10 mm settlement and 51 mm horizontal displacement. Unserved contacts remained at 81–83 μΩ, whereas field-served contacts showed displacement-sensitive, non-monotonic resistance changes. A finite element model of 24 contact fingers with assembly-induced prestress was developed. Contact pressures were calculated under normal, settlement, and combined settlement—horizontal displacement conditions. Normal force was integrated over each contact area, and zero pressure denoted contact loss. The force, contact length, and equivalent contact width were used in a cylinder-on-flat model to calculate finger resistance. These resistances were connected in parallel and calibrated against the measured normal-state resistance of 83.57 μΩ. Settlement redistributed load from lower to upper fingers, while further horizontal displacement concentrated contact on one side; eastward displacement caused all bottom-row fingers to lose contact. Electrothermal simulation showed little temperature change while most fingers remained in contact, but temperatures exceeded 130 °C after bottom-row contact loss. Thus, total resistance can conceal local degradation, while load redistribution and current concentration increase Joule heating in remaining paths and explain burnout.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Investigation on Electromagnetic–Thermal–Mechanical Multi-Physics Field Characteristics of GIS Disconnector Under Different Contact ConditionsEnergies · 2026
- Edge-localization damage mechanism in electrical contact at the micro-asperity scaleCell Reports Physical Science · 2026
- Overheating Characteristics of Contact Defects in the Transition Circuit of Oil-immersed Power Transmission Equipment On-Load Tap ChangerEngineering Research Express · 2026
- Modeling and Applicability of Nonlinear RDDS for Controlled Closing of 550 kV SF6 Circuit BreakersEnergies · 2026
- From Thermal Ablation to Mechanical Fracture: Lightning-Caused Breakage of Insulated Conductors Under Thermal–Mechanical Coupling of Power-Frequency Follow Current ArcsEng · 2026
- Conditional Root-Stress Exceedance of a 220 kV Disconnect Switch Under Dynamic Slurry–Boulder Debris-Flow LoadingApplied Sciences · 2026