Energies

Mitigating the Cold-Pane Effect: Empirical Evaluation of Active Glazing for Enhanced Thermal Comfort in Near-Zero-Energy Buildings

Hanna Koshlak

Key points

From the paper's conclusion
  • In conclusion, dynamic electro-thermal modulation effectively eliminates the perimeter cold sink, theoretically permitting up to a 100% WWR ceiling and relaxing the restrictive architectural constraints of conventional passive glazing under extreme winter conditions.

Abstract

The transition to near-zero-energy buildings requires advanced envelopes to mitigate winter thermal losses and the “cold-pane” effect inherent to passive highly glazed façades. This study empirically evaluates an active triple-glazed unit with an integrated flexible heating foil to enhance thermal comfort. A dual-zone climatic chamber simulated severe sub-zero conditions down to −25 °C, utilizing high-resolution thermography, heat-flux sensor arrays, and Fanger’s criteria to quantify conjugate heat transfer and local discomfort. The results indicate that passive operation at −25 °C depresses inner surface temperatures, yielding severe perimeter dissatisfaction (predicted percentage of dissatisfied, PPD > 20%) and restricting the permissible window-to-wall ratio (WWR) to 22.7% to meet Category A comfort standards. Conversely, activating the heating setpoint to 40 °C establishes a near-adiabatic thermal barrier that neutralizes radiant asymmetry, suppresses convective downdraughts, and restores microclimatic stability (PPD < 10%). In conclusion, dynamic electro-thermal modulation effectively eliminates the perimeter cold sink, theoretically permitting up to a 100% WWR ceiling and relaxing the restrictive architectural constraints of conventional passive glazing under extreme winter conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers