Active Fault-Tolerant Control for DFIG-Based Wind Energy Conversion Systems Using a Sensor FDI and a Novel Reconfiguration Framework
Naziha Chouider, Karim Beddek, Emad Abd-Elrady, Karim Benalia, Mohamed Zerrougui, Rezki Haddouche, Hamed Aly, Mohamed I. Mosaad
Key points
From the paper's conclusion- The proposed framework provides a structured approach to active control reconfiguration for improved reliability and resilience to faults in DFIG-based WECSs.
Abstract
Doubly Fed Induction Generator (DFIG)-based Wind Energy Conversion Systems (WECSs) rely on accurate sensor measurements to ensure stable operation and effective power conversion. However, sensor faults can compromise control performance and system reliability and lead to unscheduled shutdowns if they are not promptly detected and accommodated. This paper presents an Active Fault-Tolerant Control (AFTC) framework for a grid-connected DFIG-based WECS, integrating an existing sensor Fault Detection and Isolation (FDI) methodology with a novel control reconfiguration framework. The inherited FDI module detects and isolates sensor faults, while the proposed reconfiguration framework automatically selects an appropriate compensation strategy according to the number of simultaneously faulty sensors. Pure Measurement Compensation (PMC), Hybrid Measurement-Estimation Compensation (HMEC), and Pure Estimation Compensation (PEC) are employed for single-, double-, and triple-sensor fault scenarios, respectively. These strategies replace or reconstruct faulty sensor measurements within the affected control loops using available healthy or estimated signals. The proposed framework is implemented in MATLAB/Simulink and evaluated under additive and multiplicative sensor fault scenarios. The decision function reaches the detection threshold approximately 0.4 ms after fault injection, while the effective fault identification and isolation signal is activated within approximately 2.4 ms, followed by the activation of the corresponding compensation strategy. The simulation results demonstrate that the proposed reconfiguration strategies for the AFTC framework maintain continuous converter operation and satisfactory dynamic performance following fault diagnosis. The proposed framework provides a structured approach to active control reconfiguration for improved reliability and resilience to faults in DFIG-based WECSs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Digital protection of DFIG-based wind farms using machine learning and FRT‑based timing adjustmentScientific Reports · 2026
- Unified Fault Ride‐Through Control of DFIG Wind Turbines via Adaptive Flux Damping and Disturbance‐State SeparationInternational Journal of Circuit Theory and Applications · 2026
- Simultaneous Reconstruction of Actuator and Sensor Faults in PMSG-Based Wind Turbines Under Various Anomaly Profiles: A Takagi-Sugeno Fuzzy Observer Approach.Sensors (Basel, Switzerland) · 2026
- Improved linear active disturbance rejection control for mitigating subsynchronous control interaction in DFIG systems.ISA transactions · 2026
- An improved diagnostic methodology for rotor electrical unbalance fault and its effects on power converters in DFIGs using RLMD-based signal decompositionEngineering Research Express · 2026
- Stability Assessment Method for DFIG-Based Wind Energy SystemsAlgorithms · 2026