Energies

Rationed Demand: Temperature Extremes and Industrial Electricity Use in China

Zhiqiang Lan, Xingjin Yu, Jingyi Zhang, Guoyao Wu

Key points

From the paper's conclusion
  • Industrial heat exposure should therefore be assessed on total electricity consumed rather than on purchased electricity alone—a measurement distinction with direct consequences for reserve planning, demand-response baselines, and climate-damage assessment in energy markets pursuing sustainable development goals.

Abstract

Electricity recorded at the utility meter need not equal electricity demanded when extreme weather tightens supply. Using a daily panel of Chinese industrial electricity use covering 26 provinces and 43 industries from 28 August 2022 to 27 August 2025, we distinguish metered grid deliveries from total client-side use, which also includes captive-plant generation and self-consumed photovoltaics. Aggregate industrial use follows a U-shaped temperature response with its minimum at 15–20 ∘C, and industry responses vary widely: cooling-sensitive activities increase use significantly, while the energy-intensive branches show negative point estimates that are individually indistinguishable from zero after false-discovery correction. Heat exposure initially raises use—front-loading activity by 1.0% on the day after onset—and daily-shock local projections that reference each shock day’s heat-elevated baseline turn negative after three days, reaching −2.7% at day 21; anchored instead on spell onsets with a clean pre-event baseline, use 21 days later is statistically indistinguishable from its pre-event level, so the long-horizon decline reflects normalization rather than established production losses. At 30 ∘C or above, total use rises by 9.1%, purchased electricity by only 6.9%, and captive generation rises sharply; the client-to-purchase wedge widens by 2.3 log points at 30 ∘C or above (p<0.001) and remains significant when self-consumed photovoltaics are excluded, while every cold-side wedge is insignificant. On the cold side, purchased and total electricity move one-for-one with no detectable on-site response. This asymmetry is consistent with rationing masking: delivered electricity understates the electricity that firms would use absent a binding supply constraint. Wild-cluster bootstrap inference supports the 30 ∘C-or-above response. Industrial heat exposure should therefore be assessed on total electricity consumed rather than on purchased electricity alone—a measurement distinction with direct consequences for reserve planning, demand-response baselines, and climate-damage assessment in energy markets pursuing sustainable development goals.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Rationed Demand: Temperature Extremes and Industrial Electricity Use in China — Science Skim