Electronics

Manufacturing-Process Dose Estimation for HBM During PCB X-Ray Inspection: Effects of PCB Attenuation, Package Structure, and Backscatter

Sanghyeon Baeg, Myungsun Chun, Sung Hoon Chung, Jeonghwan Kim, Geunyong Bak, Sang Hoon Jeon

Key points

From the paper's conclusion
  • HBM exposure during PCB X-ray inspection cannot be estimated from machine settings or static geometry alone; PCB/package attenuation, scan trajectory, component location, and backscatter must be considered.

Abstract

This work evaluates the accumulated dose at a High Bandwidth Memory (HBM)-relevant location during printed circuit board (PCB) X-ray inspection under real manufacturing conditions. Measurements used an Omron VT-X750 3D CT X-ray inspection system at 115 kV and 130 μA with 1 mm Al filtration. A silicon PIN diode dosimeter at selected HBM locations recorded the dose rate and accumulated dose during the inspection scan. HBM-relevant exposure was strongly affected by PCB attenuation, HBM/package attenuation, scan position, and backscatter. The 3 mm PCB reduced the dose rate by approximately one order of magnitude relative to the direct-beam reference, and the additional HBM attenuation corresponded to an effective Cu thickness of approximately 0.15–0.16 mm. After PCB transmission, most of the remaining exposure was attenuated in the HBM/package structure. Combining this estimate with the image-sensor-side backscatter gives an HBM-relevant exposure estimate of approximately 75% of the PCB-transmitted exposure (average dose-rate equivalent approximately 0.46 mGy(Si)/s), an operational value derived from detector-dose differences rather than a measured absorbed dose in the HBM dies. The dose-rate waveform showed that exposure at the HBM location accumulates through transient events as the beam scans the PCB. HBM exposure during PCB X-ray inspection cannot be estimated from machine settings or static geometry alone; PCB/package attenuation, scan trajectory, component location, and backscatter must be considered.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Manufacturing-Process Dose Estimation for HBM During PCB X-Ray Inspection: Effects of PCB Attenuation, Package Structure, and Backscatter — Science Skim