Interfacial Band Engineering in Solution-Processed CsPbBr3/Cs2AgBiBr6 Thin-Film Heterostructure for X-ray Detectors with High Sensitivity and Reduced Dark Current
Sellan Premkumar, Krishnaraj Lavanya, Ganapathi Bharathi, Sakthivel Chandrasekar, Pitchaikannu Venkatraman, Din Nasrud, Devaraj Nataraj, Byung Seong Bae,
Key points
From the paper's conclusion- These results demonstrate that CsPbBr3/Cs2AgBiBr6 heterostructure engineering provides a practical strategy for developing low-dark-current, high-sensitivity perovskite thin-film X-ray detectors.
Abstract
Metal halide perovskites are promising materials for direct X-ray detection owing to their strong X-ray absorption, solution processability, and efficient charge separation and transport. However, thin-film perovskite detectors usually suffer from trap-assisted recombination and grain-boundary-limited charge transport, while single-crystal devices often show relatively high dark current. Herein, we report a solution-processed CsPbBr3/Cs2AgBiBr6 heterostructure thin-film X-ray detector with suppressed leakage current and improved charge extraction through interfacial band engineering. Structural, optical, and morphological analyses confirmed the formation of crystalline perovskite films with a well-defined CsPbBr3/Cs2AgBiBr6 interface. Under X-ray irradiation, the CsPbBr3/Cs2AgBiBr6 heterostructure device exhibited the photocurrent values of ∼4.57–9.52 nA over the dose rate of 120 to 600 µGy s–1. Although this photocurrent is lower than that of the single-crystal device, the hybrid detector exhibited better device performance with improved sensitivity and good signal-to-noise-relevant performance. The heterostructure thin film detector has achieved sensitivities of 171, 112, and 92 µC Gy–1 cm–2 at dose rates of 120, 240, and 360 µGy s–1, respectively. Based on the SNR = 3 detection criterion, the heterostructure exhibited the lowest detectable dose rate of 34.9 µGy s–1. These results demonstrate that CsPbBr3/Cs2AgBiBr6 heterostructure engineering provides a practical strategy for developing low-dark-current, high-sensitivity perovskite thin-film X-ray detectors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Equal-Proportion Organic-Inorganic-Mixed Cation Perovskite Single Crystalline Heterojunctions Enable High-Performance X-ray Detection.ACS applied materials & interfaces · 2026
- Heterostructure engineering for efficient halide perovskite X-ray detectors.iScience · 2026
- Rapid Low‐Temperature In‐Situ Liquid Epitaxy Toward Oriented Perovskite Heterojunctions for High‐Performance X‐Ray DetectionLaser & Photonics Reviews · 2026
- Graphene-Perovskite composite structure facilitates High-Performance X-ray detectors with low detection limitsAdvanced Composites and Hybrid Materials · 2025
- Advancements in Metal Halide Perovskites and their Derivatives for Direct‐Type X‐Ray DetectorsSmall · 2025
- In Situ Directional Growth of 2D/3D Perovskite Hetero-Crystals for Highly Sensitive and Stable X-ray Imaging.ACS nano · 2026