A Unified Control and Fault Diagnosis Framework for Single-Area Load Frequency Control: Addressing Sensor Bias Fault Insensitivity in Integral Control Approaches
Ali M. H. Kadhim, Ahmed Al Ameri, Adnan Alamili, Mamadou Baïlo Camara
Key points
From the paper's conclusion- The results are compared with an integral state-feedback approach using frequency-regulation and control-effort metrics.
Abstract
This paper presents a unified control and fault diagnosis (UCFD) framework for single-area load frequency control (LFC) systems subject to load disturbances and sensor bias faults. Although integral-based LFC can eliminate steady-state frequency errors under nominal conditions, persistent sensor biases may be interpreted as genuine frequency deviations, resulting in erroneous control actions. To address this limitation, the proposed framework replaces integral action with a state-feedback and feedforward control structure and employs two dedicated observers: an augmented-state observer for reconstructing the system states and sensor bias as an additional state, and a residual-generation observer for generating a residual associated with load disturbances. By explicitly incorporating the measured load disturbance into the augmented observer, the proposed approach separates physical load variations from sensor-induced measurement errors and enables unbiased state reconstruction. The residual-generation observer, together with an auxiliary first-order compensator, is then used for load-disturbance rejection, while sensor bias accommodation is performed at the state-estimation level. An analytical expression for the compensator gain is derived from the steady-state disturbance-rejection condition, while its time constant is selected to provide appropriate separation between observer and compensation dynamics. The proposed framework is evaluated through four simulation cases involving load disturbances and sensor bias faults with different temporal profiles, including a combined scenario with model-parameter uncertainty and stochastic load demand. The results are compared with an integral state-feedback approach using frequency-regulation and control-effort metrics. Although integral control provides slightly better nominal performance, the proposed framework achieves substantially improved frequency regulation under faulty conditions and maintains zero steady-state frequency deviation in the presence of persistent sensor bias. Moreover, under faulty and uncertain conditions, the proposed framework reduces both the cumulative squared control effort and the peak control demand, demonstrating enhanced resilience to sensor-bias faults without imposing excessive actuator requirements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI-based fault diagnostic framework for load frequency control in modern power systemsResults in Engineering · 2026
- Resilient load frequency control of multi-area power systems with packet-loss mitigation over lossy communication linksEngineering Research Express · 2026
- Resilient Distributed Observer-Based Fault-Tolerant Control for Islanded AC Microgrids Subject to Actuator Fault and Saturation ConstraintsIEEE Transactions on Consumer Electronics · 2026
- Delayed Load Frequency Regulation via a Load-Disturbance-Integrated Integral Sliding ManifoldEnergies · 2026
- A Framework for Guaranteed Active Fault Diagnosis with Applications to Aircraft SystemsarXiv · 2026
- Learning-Based Augmentation and Adaptation for Grid Sim-to-Real Model DiscrepancyarXiv · 2026