Accurate and Computationally Efficient Lookup-Table-Based Thermistor Temperature Conversion for Embedded Systems
Min Gin Kim, Mun Ho Ryu, Jong Dae Kim
Key points
From the paper's conclusion- These results demonstrate that LUT resolution can be selected according to the operating temperature range to achieve a practical trade-off among numerical approximation error, memory usage, and computational cost.
Abstract
Lookup-table (LUT)-based temperature conversion can reduce the computational cost of nonlinear thermistor calibration, but full-resolution LUTs require substantial memory in resource-constrained embedded systems. This study systematically evaluates a reduced ADC-indexed LUT with direct interval indexing and linear interpolation for temperature conversion using four commercial negative temperature coefficient (NTC) thermistors. A dense reference resistance–temperature relationship was generated from manufacturer data, and the voltage-divider reference resistance was optimized considering ADC quantization. The reported errors therefore represent numerical approximation errors relative to the nominal manufacturer-derived R–T characteristics rather than absolute sensor measurement accuracy. Reduced LUT entries were reconstructed by least-squares optimization, and the effects of LUT resolution and operating temperature range were evaluated using a 12-bit ADC baseline. Over a wide temperature range of −38–123 °C, an 8-bit LUT maintained RMSE, maximum absolute error, and 95th-percentile error comparable to or lower than those of a five-parameter Hoge-3 calibration equation. Over the narrower 45–103 °C range relevant to thermal cycling for real-time polymerase chain reaction, the LUT could be reduced to 6 bits while maintaining comparable numerical approximation error relative to the manufacturer-derived reference characteristic. For the floating-point implementations evaluated in this study, the reduced LUT achieved execution-time speed-ups of 10.6×, 12.7×, and 9.2× on Cortex-M4F, Cortex-M0+, and 8-bit RISC microcontrollers, respectively, relative to the five-parameter equation. These results demonstrate that LUT resolution can be selected according to the operating temperature range to achieve a practical trade-off among numerical approximation error, memory usage, and computational cost.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Metrological Validation of Low-Cost DS18B20 Digital Temperature Sensors Using the TH-001 Procedure: Calibration Models, Uncertainty, and ReproducibilityMetrology · 2026
- Feature calibration-enabled fine spatial resolution temperature demodulation with RDTS system.Optics express · 2026
- Conversion of Reported Temperatures from Historical Scales to the ITS-90International Journal of Thermophysics · 2026
- Microclimate Temperature Sensor Performance Is Good but Boosted by a Simple Calibration Against a Research-Grade Standard.Ecology and evolution · 2026
- Puiseux-Type Resolution Expansion of the Settling-Time Expression for an N-Bit PWM DAC with a First-Order RC FilterElectronics · 2026
- A High-Accuracy Delay-Tap Calibration Method for 100 MHz Time-Mode Signal ProcessingElectronics · 2026