Microclimate Temperature Sensor Performance Is Good but Boosted by a Simple Calibration Against a Research-Grade Standard.
Daniel Harnisch, Marko Smiljanić, Steffen Schulz, Joraine Schmoldt, Martin Wilmking
Institute of Botany and Landscape Ecology University of Greifswald Greifswald Germany.
Key points
From the paper's conclusion- We recommend sensor and deployment specific calibrations.
Abstract
Small, self-sufficient and affordable temperature loggers are widely used in ecological and biogeographical studies, but their accuracy, precision and possible lags relative to research grade sensors are incompletely quantified; simple, field applicable calibration procedures are needed to improve data quality and comparability.We evaluated four commonly used low-cost loggers (HOBO U23 001A, iButton DS1925L F5#, TOMST TMS 4, TOMST Thermologger) against a Campbell Scientific EE181 L reference in a climate chamber (PERCIVAL LT 36VLX). Three replicates per logger type recorded at 5-min intervals across six 24-h cooling-warming cycles. The chamber was set to cycle between -10°C and +35°C; however, the sensors recorded an actual achieved range of -11.5°C to +31.5°C. Data were binned in 5°C steps to assess accuracy and precision across the gradient; we tested for time lags and derived linear, sensor specific self-calibration formulas of the form T adj = T sensor - (a + b × T sensor).All loggers remained within ±1°C of the reference across the tested range, with larger errors at cold temperatures and improved performance at warmer temperatures. The EE181 L showed within-sensor precision < ±0.1°C at ~23°C; low-cost loggers achieved within-sensor precision of ±0.10°C-0.15°C. All low-cost devices exhibited short time lags of up to a few minutes in tracking temperature changes; a 5-min timestamp shift compensated for the lag of HOBO sensors. Applying linear self-calibration substantially reduced RMSE for all devices (e.g., iButton RMSE 0.46°C → 0.08°C; HOBO 0.22°C → 0.16°C) and improved accuracy to at least ±0.25°C across temperatures.Common low-cost loggers provide cost effective microclimate data with high precision and adequate accuracy for many field studies but show systematic, temperature dependent offsets and short temporal lags that warrant correction. We recommend sensor and deployment specific calibrations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Metrological Validation of Low-Cost DS18B20 Digital Temperature Sensors Using the TH-001 Procedure: Calibration Models, Uncertainty, and ReproducibilityMetrology · 2026
- Comparability of Archived Aging-Stage and Retest Records from Miniature Temperature-Pressure Sensors: Rank, Concordance, and Response Shape.Sensors (Basel, Switzerland) · 2026
- Long-Term Field Performance of Sensirion SEN54 and SPS30 Low-Cost Particle Sensors: Seasonal Variability and Correction Using Dew Point Deficit.Sensors (Basel, Switzerland) · 2026
- Accurate and Computationally Efficient Lookup-Table-Based Thermistor Temperature Conversion for Embedded SystemsElectronics · 2026
- Accuracy of Skin Temperature Sensors Under Cold and Windy Conditions: Effects of Sensor Type and Insulation.Physiological measurement · 2026
- Accurate laboratory testing of low-frequency triaxial vibration sensors under various temperature conditionsMeasurement Science and Technology · 2026