Electronics

Electromechanical and Structural Loading Effects of Virtual Synchronous Generator Control in Doubly Fed Induction Generator Wind Turbines

Ran Yao, Chao Yang, Hui Li, Hao Zhang, Yuliang Deng, Ruonan Mo

Key points

From the paper's conclusion
  • The results identify a trade-off between tower fore–aft and drivetrain loading for complete control implementations under the evaluated conditions.

Abstract

Virtual synchronous generator (VSG) control changes electromagnetic torque in doubly fed induction generator (DFIG) wind turbines and can redistribute structural loading. This study couples Fatigue, Aerodynamics, Structures, and Turbulence (FAST) v8.16 with MATLAB/Simulink to compare vector control and VSG control with current-aligned protection. A six-unit electrical equivalent is coupled to one flexible WindPACT 1.5 MW turbine through consistent coordinate, speed, torque, and power-base mappings. Load-step responses illustrate transient electromechanical coupling, and three paired turbulent realizations at a nominal wind speed of 9 m/s quantify short-term fatigue loading. The 1 Hz damage-equivalent loads (DELs) are evaluated over 60–120 s using unbinned rainflow counting without mean-stress correction. Relative to vector control, VSG changes the mean DEL by −4.43% for tower fore–aft, −0.06% for tower side-to-side, +24.76% for drivetrain torque, +1.88% for blade flapwise, and −0.67% for blade edgewise loading. Numerical-resolution and initial-state checks show that the smaller differences require cautious interpretation. The results identify a trade-off between tower fore–aft and drivetrain loading for complete control implementations under the evaluated conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Electromechanical and Structural Loading Effects of Virtual Synchronous Generator Control in Doubly Fed Induction Generator Wind Turbines — Science Skim