Photographic Tooth Color Agreement with a Reference Spectrophotometer Using DSLR and Three Smartphones in Laboratory and Clinical Evaluations with Exploratory AI Correction and Uncertainty Analysis
Mohamed Ahmed Alkhodary, Bandar Awadh Alresheedi, Ramy Elmoazen
Key points
From the paper's conclusion- Background/Objectives: To evaluate the color agreement of a digital single-lens reflex (DSLR) camera and three smartphone systems (iPhone 17 Pro Max, Google Pixel 10 Pro, Samsung Galaxy S26 Ultra) against a reference spectrophotometer for tooth shade matching, and to conduct an exploratory analysis of AI-based color correction and uncertainty flagging.
Abstract
Background/Objectives: To evaluate the color agreement of a digital single-lens reflex (DSLR) camera and three smartphone systems (iPhone 17 Pro Max, Google Pixel 10 Pro, Samsung Galaxy S26 Ultra) against a reference spectrophotometer for tooth shade matching, and to conduct an exploratory analysis of AI-based color correction and uncertainty flagging. Methods: The study comprised a laboratory phase using 29 VITA 3D-Master shade tabs and a clinical phase involving maxillary central incisors of 100 participants. Images were captured under standardized LED illumination and calibrated using a neutral gray reference. Euclidean color differences (ΔEab*) were calculated against a VITA Easyshade Advance V reference. An in silico study applied nested, participant-level cross-validation to evaluate Random Forest and Convolutional Neural Network (CNN) models for color correction, alongside uncertainty flags for identifying unreliable predictions. Results: The DSLR showed the lowest median ΔEab* in the laboratory (0.52) and clinical (0.68) phases. Clinically, 100% of Pixel, 99% of iPhone and 83% of Samsung measurements were within the selected ΔEab* ≤ 2.7 benchmark. Random Forest correction did not significantly reduce median error relative to calibrated photographs. The exploratory CNN introduced large smartphone errors, reaching ΔEab* = 7.89. Uncertainty flags detected 11/13 iPhone errors above 2.7 (84.6%; exact 95% CI 54.6–98.1%) and 18/23 Samsung errors (78.3%; 56.3–92.5%), while withholding 22% and 24% of predictions and leaving two and five errors undetected. Flagging did not establish added value over the calibrated photographic baseline. Conclusions: Under the tested conditions, the gray-card-calibrated DSLR workflow most closely agreed with the reference spectrophotometer. Smartphone performance varied by device and acquisition workflow. Random Forest correction provided no demonstrated added benefit, whereas the exploratory CNN introduced large errors in some smartphone predictions. Independent external validation is needed before AI-based correction or uncertainty flags can support clinical decisions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of Tooth Shade Selection With Conventional Methods and Artificial Intelligence-Integrated Methods: A Comparative Study.Cureus · 2026
- Clinical Shade Matching of Dental Ceramics Using Digital Devices: A Systematic ReviewCurrent Oral Health Reports · 2026
- Comparison of image quality, color accuracy, and resolution in intraoral photography using digital single lens reflex camera and smartphone cameras: A pilot studyJournal of Dental Sciences · 2025
- Comparative Analysis of Image Quality Assessment Between Digital Signal-to-Noise Ratio (SNR) Camera and Smartphone Camera for Dental Photography.Cureus · 2026
- Influence of Illumination Conditions and Cross-Polarization on DSLR-Based Clinical Tooth Color Assessment: A Comparison With Spectrophotometric Measurements.Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] · 2026
- Clinical Repeatability and Inter-Method Agreement of VITA Easyshade Advance 4.0 and Rayplicker Cobra for Tooth Shade Determination: An Exploratory Cross-Sectional Study.Diagnostics (Basel, Switzerland) · 2026