The Impact of Centrifugation Devices and Collection Tubes on Fibrin Characteristics and Growth Factor Release Under High- and Low-Speed Protocols
Oranit Bunyatratchata, Wutigri Nimlamool, Supatra Sang-in
Chiang Mai University
Key points
From the paper's conclusion- Methods: Blood samples from six healthy female volunteers were processed using three centrifuges (Duo, IntraSpin, and LMC-3000) and three collection tubes (Pyrex, A-P, and silica-coated plastic) under high- (~700× g for 12 min) and low-speed (~200× g for 8 min) protocols.
Abstract
Background: Platelet-rich fibrin (PRF) is an autologous platelet concentrate (APC) produced through blood centrifugation. Despite the development of various centrifugation systems, protocol variability continues to pose challenges in selecting the optimal method. This study investigated the effects of three different centrifuges and collection tubes on the fibrin characteristics and growth factor release in leukocyte- and platelet-rich fibrin (L-PRF) and advanced platelet-rich fibrin plus (A-PRF+). Methods: Blood samples from six healthy female volunteers were processed using three centrifuges (Duo, IntraSpin, and LMC-3000) and three collection tubes (Pyrex, A-P, and silica-coated plastic) under high- (~700× g for 12 min) and low-speed (~200× g for 8 min) protocols. Fibrin clot weight and length were assessed. Growth factor release of platelet-derived growth factor-BB (PDGF-BB) and vascular endothelial growth factor (VEGF) was quantified using ELISA. Fibrin architecture was examined via scanning electron microscopy (SEM). Results: High-speed protocols tended to produce larger clots, whereas low-speed protocols generated smaller but more biologically active matrices. The IntraSpin and Duo centrifuges yielded greater clot dimensions and higher growth factor release than the LMC-3000. While tube type had no significant effect on growth factor levels, silica-coated tubes tended to produce the largest clots. The Pyrex tubes demonstrated comparable or superior growth factor release. Conclusions: PRF quality is influenced by centrifuge design, g-force, and tube material. Low-speed protocols with certified centrifuges are recommended, and FDA-approved glass tubes may provide a reliable alternative to reduce silica-related risks. Standardization and appropriate material selection are essential for consistent, safe, and effective regenerative outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Platelet‐Rich Fibrins as Local Drug‐Delivery CarriersJournal of Periodontal Research · 2026
- Influence of Manual Double-Spin Preparation Protocols on the Cellular and Growth Factor Composition of Equine Platelet-Rich Plasma.Animals : an open access journal from MDPI · 2026
- Comprehensive Characterization of Injectable Platelet-Rich Fibrin (i-PRF): Cellular, Biochemical, Architectural, Rheological, and Release-Kinetic Profiling of Ten Independent PreparationsBiologics · 2026
- Quantification of PDGF-AB and TGF-β1 Proteins in Platelet-rich Plasma Obtained under Different Conditions.Prague medical report · 2026
- Comparative Characterization of Leukocyte-Rich Platelet-Rich Plasma (L-PRP) and Injectable Platelet-Rich Fibrin (i-PRF): A Laboratory StudyCells · 2026
- Comparing the efficacy of A-PRF and I-PRF in mandibular 3rd molar surgery with similar difficulty index: A comparative, split mouth study.Bioinformation · 2026