Biologics

Comprehensive Characterization of Injectable Platelet-Rich Fibrin (i-PRF): Cellular, Biochemical, Architectural, Rheological, and Release-Kinetic Profiling of Ten Independent Preparations

Packkyarathinam Rathinavelpandian Perunchezhian, Naveen Jeyaraman, Anandanarayan Muruganandam, Ravichandran Venkatasalam, Arulkumar Nallakumarasamy, Sathish Muthu, Sree Naga Sowndary Rajendran, Prakash Gangadaran,

Key points

From the paper's conclusion
  • These findings should be regarded as preliminary, protocol-specific reference data that require confirmation in larger donor cohorts and functional studies.

Abstract

Background: Injectable platelet-rich fibrin (i-PRF) is a second-generation autologous platelet concentrate from low-speed centrifugation of whole blood without the use of any anticoagulant. However, despite the growing use in the clinic, there are few studies that have combined data from cellular to biochemical, ultrastructural, rheological, and release-kinetic descriptors in a single cohort. Objective: To characterise i-PRF from 10 healthy donors for each of 8 pre-defined domains and determine preliminary reference physico-chemical parameters relevant to the bioactivity and injectability. Methods: Ten i-PRF preparations were made using the Low-Speed Centrifugation Concept (700 rpm, 60 g, 3 min). Samples were analysed by cellular profiling (automated haematology, flow cytometry); growth-factor measurements by ELISA and Luminex (PDGF-AA/AB/BB, VEGF, TGF-β1, IGF-1, EGF, FGF-2, HGF, BMP-2/7); ultrastructural analysis (scanning electron microscopy); clot kinetic assessment; oscillatory rheometry; and 14-day cumulative release kinetics. Results: The mean platelet enrichment was 940 ± 56 × 103/µL, leukocytes 25.5 ± 2.7 × 103/µL, and no significant erythrocytes were seen. TGF-β1 (42.0 ± 3.3 ng/mL) and IGF-1 (82.4 ± 9.1 ng/mL) dominated; BMP-2 and BMP-7 were detected at lower concentrations (65.7 ± 9.4 and 40.3 ± 6.8 pg/mL, respectively); VEGF and PDGF-BB showed inter-sample CVs below 10%. Fibrin fibre thickness was 142 ± 13 nm and porosity 68.9 ± 2.9%. The values for storage modulus G′ (133 ± 11 Pa) and tan δ (0.19) indicate a soft elastic gel. In phosphate-buffered saline, cumulative release continued until day 14, with 46% released by day 3 and >90% by day 10. Conclusions: i-PRF prepared according to the low-speed concept provided, under the present single-protocol conditions, a biologic with consistent cellular, biochemical, ultrastructural and rheological signatures suitable for a minimally invasive injectable format. These findings should be regarded as preliminary, protocol-specific reference data that require confirmation in larger donor cohorts and functional studies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers