Real-World Clinical Evaluation of an Artificial Intelligence Application for Acute Cervical Spine Fracture Detection on CT
Thomas Bourmaud, Brieg Dissaux, Lise Chalabreysse, Elsa Magro, Jean-Christophe Gentric, Julien Ognard
Key points
From the paper's conclusion- This study evaluated an AI application on dedicated non-contrast cervical spine CTs and conducted a ‘stress test’ on contrast-enhanced whole-body trauma CTs.
Abstract
Background/Objectives: Artificial intelligence (AI) shows promise for acute cervical spine fracture (CSFx) detection, but its performance across diverse computed tomography (CT) protocols in unselected emergency workflows requires validation. This study evaluated an AI application on dedicated non-contrast cervical spine CTs and conducted a ‘stress test’ on contrast-enhanced whole-body trauma CTs. Methods: This retrospective study included 724 consecutive adults undergoing cervical spine or whole-body CT at a Level I trauma center (November 2023–February 2025). Disagreements with retrospective review defaulted to the original senior-validated clinical report, reflecting agreement with routine practice rather than an independent expert consensus. Results: Overall, 79/724 patients had acute CSFx (10.9% prevalence), including 54/627 (8.6%) imaged for acute initial trauma. On non-contrast CTs (n = 298), the AI achieved 88.0% sensitivity (95% CI: 76.2–94.4), 88.3% specificity, 60.3% positive predictive value (PPV), and 97.3% negative predictive value (NPV); in the acute-initial-trauma non-contrast subgroup (n = 204), sensitivity was 80.0% (20/25; 95% CI: 60.9–91.1). On contrast-enhanced CTs (n = 426), sensitivity was 86.2%, whereas specificity was lower (75.1%), associated with arterial opacification artifacts and protocol-group differences. Exact vertebral level localization was achieved in 60/69 (87.0%) detected positive examinations and 60/79 (75.9%) fracture-positive examinations. Conclusions: Evaluated for agreement with routine senior-validated clinical reports, the AI showed high sensitivity and NPV in an unselected cohort, suggesting potential triage utility, though acute-initial-trauma non-contrast sensitivity was lower (80.0%) and workflow impact remains unmeasured. Arterial-phase acquisitions were associated with higher false-positive rates, warranting protocol-aware interpretation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deep Neural Networks for Automatic Detection and Classification of Traumatic Cervical Vertebral Fractures on CT Scans.Clinical spine surgery · 2026
- Artificial intelligence in spinal fracture imaging: from clinical application to translational promise.Frontiers in medicine · 2026
- Prospective Diagnostic Accuracy and Technical Feasibility of Artificial Intelligence-Assisted Rib Fracture Detection on Chest Radiographs: Observational StudyJMIR Medical Informatics · 2026
- Deep learning framework for the assessment of odontoid fractures on cervical CT: optimization of sensitivity and specificityBMC Medical Imaging · 2026
- AI-enhanced routine CT for opportunistic osteoporosis screening and risk assessment.Skeletal radiology · 2026
- From underdiagnosis to scalable screening: Applications of artificial intelligence for vertebral compression fracture detection - a systematic review and meta-analysis of diagnostic performance.Osteoporosis and sarcopenia · 2026