From underdiagnosis to scalable screening: Applications of artificial intelligence for vertebral compression fracture detection - a systematic review and meta-analysis of diagnostic performance.
Hsuan-Yu Chen, Linjun Yang, Gwen Wilson, Milos Brkljac, Monty S Khela, Kellen L Mulford, Cody C Wyles
Orthopedic Surgery Artificial Intelligence Laboratory (OSAIL), Department of Orthopedics, Mayo Clinic, Rochester, MN, USA. · Mayo Clinic Libraries, Mayo Clinic, Rochester, MN, USA.
Key points
From the paper's conclusion- AI models demonstrate high diagnostic accuracy for VCF detection, particularly in CT imaging. However, improved detection alone does not ensure better outcomes, as substantial treatment gaps persist. The clinical impact of AI depends on rigorous prospective external validation and integration into structured osteoporosis care pathways, linking automated identification to timely evaluation and secondary fracture prevention.
Abstract
OBJECTIVES: Vertebral compression fractures (VCFs) are common and often missed on routine imaging. We systematically reviewed the diagnostic performance of artificial intelligence (AI) for VCF detection. METHODS: A systematic review and meta-analysis were conducted following PRISMA 2020 and PROSPERO registration by searching Ovid Medline, Embase, and Central from January 1, 2020, to November 18, 2025, for studies using AI models for VCF detection and diagnosis. Risk of bias was assessed with QUADAS-2. Studies with complete 2 × 2 data were pooled using random-effects meta-analysis, with subgroup analyses by modality. RESULTS: Fifty-one studies were included. Thirty-seven contributed to meta-analysis with around 259 190 participants and 45,346 VCF patients. Original radiology reports missed > 50% of incidental VCFs in many cohorts (up to 81%). The overall sensitivity of AI-assisted VCF detection was 85.0% (95% CI 84.2%-85.7%) and specificity 94.6% (95% CI 92.8%-95.9%). The positive and negative likelihood ratios were 15.4 and 0.16. At 22% pre-test probability, post-test probability was 77.7% after a positive AI result and 4.1% after a negative result. CT-based AI models performed best (sensitivity: 88.0%, specificity: 97.5%), while X-ray-based AI models showed lower sensitivity (79.2%) with high specificity (95.1%). CONCLUSIONS: AI models demonstrate high diagnostic accuracy for VCF detection, particularly in CT imaging. However, improved detection alone does not ensure better outcomes, as substantial treatment gaps persist. The clinical impact of AI depends on rigorous prospective external validation and integration into structured osteoporosis care pathways, linking automated identification to timely evaluation and secondary fracture prevention.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Classification of vertebral compression fractures using CT-based radiomics: a viable alternative to MRIBMC Medical Imaging · 2026
- Beyond Bone Density Alone: Opportunistic Identification of Vertebral Compression Fractures in Breast Cancer Survivors Using Artificial Intelligence-Derived Vertebral Bone Density and Paraspinal Muscle-Fat Metrics.Journal of clinical medicine · 2026
- AI-enhanced routine CT for opportunistic osteoporosis screening and risk assessment.Skeletal radiology · 2026
- Preventing fragility fractures: AI-based opportunistic osteoporosis detection in routine CT .Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2026
- Diagnostic accuracy of AI-assisted versus independent physician interpretation for bone fractures: a systematic review and meta-analysis.European radiology experimental · 2026
- A Multimodal large language model-based triage tool for osteoporotic vertebral compression fractures using posture and movement videos.NPJ digital medicine · 2026