The Lead Tip Beyond the Myocardial Contour: A Narrative Review of Cardiac Implantable Electronic-Device Perforation Detected by Computed Tomography
Yangyang Ji, Chu Guo, Peng Li, Yuan Li, Huaisheng Ding
Key points
From the paper's conclusion- Computed tomography (CT) frequently shows the tip of a cardiac implantable electronic device (CIED) lead, or the fixation tine of a leadless pacemaker, beyond the myocardial contour in patients without symptoms or hemodynamic compromise.
Abstract
Computed tomography (CT) frequently shows the tip of a cardiac implantable electronic device (CIED) lead, or the fixation tine of a leadless pacemaker, beyond the myocardial contour in patients without symptoms or hemodynamic compromise. What such an image means is a separate question the literature has not settled. This narrative review sets out the definitions in use, the three CT cohorts behind the argument, the observed natural history and the management choices that follow, keeping anatomical observations apart from clinical events. Reported penetration was 15/100 conventional-device recipients, 26/463 conventional leads (25/271 patients) and 15/88 leadless recipients; a conference abstract reported 12 of 31 leadless recipients (38.7%). Sampling, observation unit, device structure and imaging interval differ across these sources, so none supports an incidence figure or a device comparison. No clinical perforation developed over 2.7 years among 25 patients with conventional-lead findings, and no related adverse event occurred over a mean of 12.4 months among 15 leadless recipients; both figures concern findings already silent at CT, neither cohort sized the residual risk, and imaging accuracy measured in recognized perforation does not carry over to screening. Implantation guidance sets no screening or intervention criteria. What the evidence supports is individual assessment, not routine CT screening, universal intervention or fixed warning thresholds. Assessment criteria, a reporting checklist, and emerging imaging and automation tools are summarized.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Where do leadless pacemakers really land? Insights from a CT validated multicenter investigationEuropean Heart Journal · 2026
- Uncommon but Critical Cardiac Abnormalities on Routine Chest Computed Tomography.Journal of thoracic imaging · 2026
- Subacute Apical RV Lead Microperforation in CRT Implantation: An Electrical Diagnosis.JACC. Case reports · 2026
- Recurrent Inappropriate ICD Shocks Following Lead Fracture Due to Blunt Chest Trauma: A Case Report.Indian pacing and electrophysiology journal · 2026
- Fatal Cardiac Tamponade After Central Venous Catheterization: Autopsy Evidence of Guidewire-Induced Right Ventricular PerforationForensic Sciences · 2026
- Cardiac Computed Tomography in Infective Endocarditis: A Radiological Perspective on Structural Complications and Emerging Diagnostic Technologies.Tomography (Ann Arbor, Mich.) · 2026