Diagnostic Performance of 96-Channel Magnetocardiography for Angiographically Significant Coronary Stenosis in Patients with Chest Pain and Clinically Suspected Angina: A Two-Center Post Hoc Analysis.
Osung Kwon, Youngwoo Jang, Yeonjik Choi, Junghoon Lee, Yoonsun Won, Joonpyo Lee, Kyung Eun Ha, Minsu Kim,
Division of Cardiology, Department of Internal Medicine, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea. · Division of Cardiology, Department of Internal Medicine, Gachon University Gil Medical Center, Incheon 21565, Republic of Korea.
Key points
From the paper's conclusion- Background/Objectives: We evaluated the diagnostic performance of 96-channel magnetocardiography (MCG) for angiographically significant coronary stenosis in patients with chest pain and clinically suspected angina.
Abstract
Background/Objectives: We evaluated the diagnostic performance of 96-channel magnetocardiography (MCG) for angiographically significant coronary stenosis in patients with chest pain and clinically suspected angina. Methods: This two-center post hoc analysis included 137 participants with paired resting (Rest) and post-exercise recovery recordings. The anatomical reference required visually assessed stenosis ≥70% in a vessel with a reference diameter ≥ 2.5 mm. A predefined Total Score ≥ 2 indicated a positive MCG test. Results: The cohort included 37 reference-positive and 100 reference-negative participants. Rest and post-exercise AUCs were 0.710 (95% CI 0.612-0.801) and 0.815 (0.730-0.889), respectively. The direct paired AUC difference was 0.106 (95% CI 0.004-0.207; paired DeLong p = 0.041). A separate exploratory fitted-model comparison yielded an AUC difference of 0.097 (95% CI 0.031-0.214). At Total Score ≥ 2, Rest sensitivity and specificity were 64.9% and 74.0%. Post-exercise sensitivity, specificity, positive predictive value, and negative predictive value were 83.8% (95% CI 68.9-92.3), 77.0% (67.8-84.2), 57.4% (44.2-69.7), and 92.8% (85.1-96.6), respectively. Post-exercise MCG produced six false-negative and 23 false-positive results. Paired sensitivity and specificity differences were not statistically significant. Conclusions: In this selected cohort, post-exercise MCG showed higher discrimination than Rest MCG for the study-defined anatomical target. The findings support further evaluation as an adjunctive electrophysiological test; they do not establish physiological ischemia detection or justify deferring indicated anatomical assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Magnetocardiography for Distinguishing Obstructive Coronary Heart Disease and Coronary Microvascular Dysfunction: A Feasibility StudyCardiology · 2026
- AI-enabled OPM-magnetocardiography for pre-angiography infarct-related artery probability estimation in NSTEMI: a two-campus prospective cohort study.European heart journal. Digital health · 2026
- Is magnetocardiography a breakthrough medical device ready to support first-line clinical diagnosis of myocardial ischemia?European Heart Journal · 2026
- Magnetocardiographic Rotation Score and Arrhythmic Endpoints in Primary-Prevention ICD Recipients: An Exploratory Substudy of the Magneto-SCD Trial.Journal of clinical medicine · 2026
- Explainable deep learning on magnetocardiography detects coronary artery disease, left ventricular dysfunction, and arrhythmia risk from a single scanEuropean Heart Journal · 2026
- Prognostic impact of persistent microvascular obstruction on cardiac magnetic resonance after STEMI: a systematic review and meta analysisEuropean Heart Journal · 2026