European heart journal. Digital health

AI-enabled OPM-magnetocardiography for pre-angiography infarct-related artery probability estimation in NSTEMI: a two-campus prospective cohort study.

Linqi Liu, Yilin Pan, Jie Ji, Hai Gao, Yanlong Ren, Min Zhang, Mingduo Zhang, Ming Ding,

Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Road, Chaoyang District, Beijing 100029, China. · Department of Cardiovascular Surgery, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China.

Observational · n=611

Key points

From the paper's conclusion
  • We evaluated whether a noninvasive 90-second optically pumped magnetometer magnetocardiography (OPM-MCG) recording can estimate pre-angiography IRA probabilities in these patients and provide information beyond standard-care variables.

Abstract

AIMS: Identifying the infarct-related artery (IRA) before coronary angiography in non-ST-segment elevation myocardial infarction (NSTEMI) is difficult because current approaches have limited sensitivity. We evaluated whether a non-invasive 90-s optically pumped magnetometer magnetocardiography (OPM-MCG) recording can estimate pre-angiography IRA probabilities in these patients and provide information beyond standard-care variables. METHODS AND RESULTS: This prospective two-campus study within one hospital system included a Campus 1 development cohort (n = 493) and a geographically separate Campus 2 test cohort (n = 118). All patients underwent OPM-MCG before angiography. An XGBoost model using 65 prespecified OPM-MCG features was developed with nested cross-validation, locked, and evaluated once in Campus 2. IRA adjudication followed a core-laboratory hierarchy. Discrimination, calibration, and clinical utility were compared with ECG and TTE. Among 611 patients, 43% had LAD, 23% LCx, and 34% RCA IRA. In Campus 2, overall accuracy was 63.6%, macro-F1 was 60.0%; LAD/LCx/RCA vessel-specific areas under the receiver operating characteristic curve were 0.87/0.79/0.79 and top-1 sensitivity was 76.6%/34.5%/69.0%. Accuracy was 51.7% for matched ECG-only XGBoost and 55.9% for integrated standard care. In an exploratory stacked analysis, adding locked OPM-MCG probabilities to standard care increased accuracy to 67.8% (paired difference 11.9%, 95% CI 4.2-19.5; P = 0.008). CONCLUSION: In haemodynamically stable patients with NSTEMI already selected for invasive management, a locked OPM-MCG model provided informative vessel-level probabilities in Campus 2 and complementary signal with standard care. Performance was strongest for LAD and RCA. Prospective multicentre, cross-platform testing is needed before clinical use. TRIAL REGISTRATION NUMBER: ChiCTR2300070211.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers