Diagnostics (Basel, Switzerland)

A Modular Diabetic Retinopathy Analysis Framework for Lesion Segmentation and Severity Grading: Cross-Dataset External Validation from APTOS to Messidor-2.

Sofiane Boumeshed, Yazid Cherfa, Assia Cherfa, Noureddine Belkhamsa

Laboratoire de Physique et Chimie des Matériaux et Interfaces Avancées (LPCMIA), Département d'Électronique, Faculté des Sciences et Technologies, Université Blida 1, Blida 09000, Algeria.

Key points

From the paper's conclusion
  • Methods: A modular framework combines a ResNet-34 U-Net for lesion segmentation (IDRiD) with an EfficientNet-B0 severity grader (APTOS 2019), optionally fused with lesion-derived and frequency features.

Abstract

Background/Objectives: High in-domain accuracy of diabetic retinopathy (DR) grading models does not guarantee a similar performance for a new population. We quantify how an APTOS-trained grader degrades on an independent cohort and examine why. Methods: A modular framework combines a ResNet-34 U-Net for lesion segmentation (IDRiD) with an EfficientNet-B0 severity grader (APTOS 2019), optionally fused with lesion-derived and frequency features. The grader was evaluated zero-shot on Messidor-2 (n=1744) with bootstrap confidence intervals, four training seeds, referable-DR analysis, a discrimination-versus-calibration decomposition, a paired preprocessing ablation, and a duplicate audit. Results: Quadratic weighted kappa (QWK) fell from 0.873 (95% CI 0.831-0.909) on the APTOS test set to 0.455 (0.400-0.507) on Messidor-2; across four seeds the external QWK was 0.410±0.057. Referable-DR sensitivity fell from 92.7% to 35.0% (specificity 93.9% and 96.6%) and the AUC from 0.984 to 0.795, indicating both a loss of discrimination and a calibration shift; recalibrating thresholds with target labels (cross-validated) raised QWK only to 0.583. Omitting CLAHE reduced QWK to 0.326 (paired difference 0.129, 0.089-0.171). Thirty-three APTOS test images duplicated in the training or validation data changed QWK marginally (0.866). Lesion-feature fusion did not significantly improve grading. The segmentation Dice on lesion-containing patches was 0.51-0.68, whereas the per-image Dice was 0.21-0.61. Conclusions: In-domain agreement is a poor proxy for external performance; multi-seed reporting, explicit calibration analysis, and preprocessing control are needed before clinical use.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A Modular Diabetic Retinopathy Analysis Framework for Lesion Segmentation and Severity Grading: Cross-Dataset External Validation from APTOS to Messidor-2 — Science Skim