Benchmark Accuracy Does Not Transfer: Domain Adaptive Deep Learning for Diabetic Retinopathy Detection in a Bangladeshi Clinical Setting.
Riad Hossain, Ittekhar Mahin Abir, Ayesha Banu, Mohammed Nazim Uddin
School of Science, Engineering and Technology, Chittagong, Bangladesh. riad.h@eastdelta.edu.bd. · School of Science, Engineering and Technology, Chittagong, Bangladesh.
Key points
From the paper's conclusion- These findings quantify a substantial benchmark-to-clinic gap and show that target-domain adaptation can improve performance, while the remaining false-negative rate and single-clinic design preclude claims of clinical readiness.
Abstract
Deep learning could make diabetic retinopathy (DR) screening more accessible where ophthalmologists are scarce, but high benchmark accuracy does not guarantee reliable clinical performance. We investigate this gap using 3662 images from APTOS 2019 for source training and a balanced evaluation corpus of 500 fundus images (250 DR, 250 No-DR) from a Bangladeshi clinic, graded by a single experienced ophthalmologist. Source-trained models achieved 94.26-96.80% accuracy under tenfold cross-validation on APTOS, yet achieved only 49.4-50.6% (mean 50.0%) when applied directly to the clinical images. The resulting 44.46-46.85 percentage-point losses across all six architectures provide consistent quantitative evidence of severe domain shift. A full-cohort feature comparison yielded a classical-feature Fréchet distance of 133.49 and an MMD 2 of 0.3967 (permutation p = 0.0005 ). To recover target-domain performance, we evaluate an adaptation pipeline that integrates retinal-specific preprocessing, progressive fine-tuning with discriminative learning rates, soft-voting inference, and test-time augmentation. Aggregated out-of-fold evaluation produced 81.0% accuracy (95% Wilson CI 77.3-84.2%), 70.0% sensitivity, 92.0% specificity, 89.7% precision, and a 78.7% F1 score. Fine-tuning increased mean individual-model accuracy by 27.1 percentage points, whereas preprocessing contributed a descriptive 2.0-point increase. These findings quantify a substantial benchmark-to-clinic gap and show that target-domain adaptation can improve performance, while the remaining false-negative rate and single-clinic design preclude claims of clinical readiness.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- D-TNet: a hybrid Dense Net-transformer model for robust diabetic retinopathy detectionScientific Reports · 2025
- AI-driven detection and classification of diabetic retinopathy stages using EfficientNetB0Discover Applied Sciences · 2025
- Clinical-guided deep learning framework for diabetic retinopathy: integrating lesion-aware attention, adversarial augmentation, and uncertainty quantification.Scientific reports · 2026
- Diffusion-augmented contrastive learning for diabetic retinopathy severity classification.Frontiers in artificial intelligence · 2026
- A Modular Diabetic Retinopathy Analysis Framework for Lesion Segmentation and Severity Grading: Cross-Dataset External Validation from APTOS to Messidor-2.Diagnostics (Basel, Switzerland) · 2026
- Neural search guided CNN–transformer for diabetic retinopathy prediction from fundus imagesOptics & Laser Technology · 2026