Diagnostics (Basel, Switzerland)

Per-Patient Polyp Detection Rate of Colon Capsule Endoscopy: A Systematic Review and Meta-Analysis with Exploratory Stratification by Referral Pathway.

Ian Io Lei, Grazia Bernui Vigo, Ramesh P Arasaradnam, Anastasios Koulaouzidis

Institute of Precision Diagnostics & Translational Medicine, University Hospitals Coventry and Warwickshire NHS Trust, Coventry CV2 2DX, UK. · Department of Gastroenterology, Oxford University Hospitals NHS Foundation Trust, Oxford OX3 9DU, UK.

Meta-analysis

Key points

From the paper's conclusion
  • Background/Objectives: Colon capsule endoscopy (CCE) is a minimally invasive alternative to optical colonoscopy, but per-patient polyp detection rate (PDR), the proportion of patients with at least one visually reported polyp, varies across referral populations.

Abstract

Background/Objectives: Colon capsule endoscopy (CCE) is a minimally invasive alternative to optical colonoscopy, but per-patient polyp detection rate (PDR), the proportion of patients with at least one visually reported polyp, varies across referral populations. We estimated any-polyp and size-stratified CCE yield and explored between-study variation. Methods: MEDLINE, Embase, PubMed, and Cochrane CENTRAL were searched from 1 January 2004 to 29 July 2026. Proportions were pooled using random-intercept binomial-normal generalised linear mixed models. PROSPERO: CRD420261464937 (registration not prospective). Results: Of 44 retained studies (12,754 participants), 31 independent studies (11,310 participants) formed the primary pool. Pooled PDR was 53.2% (95% CI 46.1-60.1; prediction interval 19-85%), a descriptive average, not a performance target. Exploratory PDR was 81.2% after positive FIT (k = 4), 49.4% after incomplete colonoscopy (k = 4), and 39.9% in screening without prior FIT enrichment (k = 3); 14 studies had mixed pathways. Pooled detection was 32.7% for polyps ≥ 6 mm (prediction interval 8-74%) and 17.7% for polyps ≥ 10 mm (4-51%). Conclusions: CCE PDR is a visual yield measure, not adenoma detection or diagnostic accuracy. A global CCE PDR is not a portable quality threshold; referral-pathway estimates are descriptive and hypothesis-generating. Future quality metrics require standardised pathways, denominators, and linkage to downstream clinical outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Per-Patient Polyp Detection Rate of Colon Capsule Endoscopy: A Systematic Review and Meta-Analysis with Exploratory Stratification by Referral Pathway — Science Skim