Inter- and Intra-Observer Reliability for Colon Capsule CLEansing Assessment and Report.
Eimear Gibbons, Syafiq Ismail, Dana AlSharqi, Lisa Keating, Claire Smyth, Richard Farrell, Barry Hall, Orlaith Kelly
Department of GastroenterologyConnolly Hospital BlanchardstownBlanchardstownDublinIreland. · Department of Gastroenterology and Clinical MedicineTallaght University HospitalDublinDublinIreland.
Key points
From the paper's conclusion- A novel system named Colon Capsule CLEansing Assessment and Report (CC-Clear) has shown superior inter- and intra-observer agreement to the Leighton-Rex scale, an earlier scoring system from 2011.
Abstract
A validated scoring system for reporting of colonic cleanliness at colon capsule endoscopy (CCE) is not routinely used to date and great inter-observer variability exists. To ensure appropriate and standardised bowel cleansing reporting, a validated scoring system is of great importance. This would improve the quality of colon capsule reporting and facilitate optimisation of bowel preparation protocols by supporting research reliability. A novel system named Colon Capsule CLEansing Assessment and Report (CC-Clear) has shown superior inter- and intra-observer agreement to the Leighton-Rex scale, an earlier scoring system from 2011. This was a retrospective, single-centre study assessing the intra- and inter-observer reliability of CC-Clear. Materials and Methods Studies were identified retrospectively from the capsule database of a tertiary referral centre. In all, 30 consecutive complete CCE were included. Three expert capsule readers reviewed and reported each examination twice. Results and Conclusion The inter-observer agreement was reported as Kendall's W and was 0.8, p < 0.01. An intra-rater reliability analysis was performed between the first and second readings of the three readers. The weighted Cohen's Kappa showed that there was moderate agreement between the readings of Reader A with κ = 0.52 and p < 0.001. For Reader B, the weighted Cohen's Kappa showed moderate agreement between first and second readings, κ = 0.5 and p < 0.001. For Reader C, the weighted Cohen's Kappa revealed almost perfect agreement between reading with κ = 0.8 and p < 0.001. CC-Clear is a simple tool for the CCE reader to utilise and has been shown again here to have excellent inter- and intra-observer reliability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Associations between patient characteristics and completeness of colon capsule endoscopy in colorectal cancer screening participants: a cross-sectional studyBMJ Open Gastroenterology · 2026
- Per-Patient Polyp Detection Rate of Colon Capsule Endoscopy: A Systematic Review and Meta-Analysis with Exploratory Stratification by Referral Pathway.Diagnostics (Basel, Switzerland) · 2026
- Application of withdrawal-to-intubation ratio in assessing pattern and quality of colonoscopic intervention: a retrospective cohort analysis.Frontiers in medicine · 2026
- Misclassified and non-detected cancers by colon capsule endoscopy in screening participants: a case series from the CareForColon2015 trial.Annals of gastroenterology · 2026
- Written Recommendation to Repeat Colonoscopy within 1 Year after Inadequate Bowel Preparation: A Simple and Highly Effective Intervention.Endoscopy international open · 2026
- Research progress on bowel preparation regimens before colonoscopy: a narrative review.Frontiers in medicine · 2026