Diagnostics (Basel, Switzerland)

A Candidate Verification Gate for Reducing False-Positive Staging in a Pressure Ulcer AI Pipeline.

Dong-Hun Han, Jun-Woo Choi, Kyu Hyun Nam, Minsoo Kang

Department of Medical Artificial Intelligence, Eulji University, Seongnam 13135, Republic of Korea. · MDIS Co., Ltd., Seongnam 13135, Republic of Korea.

Observational

Key points

From the paper's conclusion
  • The findings do not establish superiority of a separate gate, patient-level generalization, clinical acceptability of missed lesions, or pressure ulcer etiology discrimination.

Abstract

Background/Objectives: A four-class stage classifier can assign a pressure ulcer stage to an erroneous detection. We evaluated supervised candidate verification and its rejection costs. Methods: This retrospective challenge-set study used a frozen detector and stage classifier with an existing binary gate threshold of 0.70. Negative evaluation data comprised 1138 Normal-labeled skin images from 347 source photographs and 328 non-pressure-wound images. A stronger source-family audit reduced the original 112-image positive subset to 94 images from 93 families; these still overlapped detector development. Additional experiments compared three source-grouped binary classifiers and paired detector fine-tuning with or without mined negative images. Results: The historical gate reduced skin images with false-positive outputs from 269/1138 (23.6%) to 54/1138 (4.7%). In the corrected positive subset, 106/107 detected lesions were retained; overall lesion recall changed from 107/110 to 106/110. Both historical false-negative lesions remain in the safety review. Newly trained You Only Look Once (YOLO) 26s, ResNet18, and MobileNetV3-small models achieved internal test-positive retention of 97.4-98.5% after separate calibration. Adding mined negatives directly to detector fine-tuning also reduced false-positive outputs. The historical gate accepted 122/147 matched non-pressure-wound candidates. Conclusions: Negative supervision reduced false-positive outputs through both modular verification and detector retraining. The findings do not establish superiority of a separate gate, patient-level generalization, clinical acceptability of missed lesions, or pressure ulcer etiology discrimination.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A Candidate Verification Gate for Reducing False-Positive Staging in a Pressure Ulcer AI Pipeline — Science Skim