From benchmark to user: an end-to-end evaluation audit of an AI-based oral health screening prototype.
Ivan Cheng Jun Char, Abdullah Sayed Ahmed Sayed, Kazuki Ichikawa, Youssif Mahmoud Gomaa Sayed, Abdurrahman Bin Milhan, Doreen Ying Ying Sim, Anand Ramanathan
School of Computer and Mathematical Sciences, University of Nottingham Malaysia, Semenyih, Selangor, Malaysia. · Department of Oral and Maxillofacial Clinical Sciences, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia.
Key points
From the paper's conclusion- Conclusion Duplication compromised the benchmark's independence without detectably changing aggregate mAP; the defects that changed what was reported or displayed lay in the labels, evaluation software, and pipeline.
Abstract
BACKGROUND: Artificial intelligence (AI) for oral screening is usually judged by aggregate detection metrics on public benchmarks whose partitions, labels, and relevance to users are rarely checked. METHODS: We audited a prototype combining a YOLOv8m detector for six conditions (1,500 test images), a DenseNet169 histopathology network, and a ResNet18 router. Under a pre-specified plan, we measured duplication across partitions, tested removal of duplicated test images against 10,000 matched controls, compared duplicated copies' labels and predictions, compared the library versions, and ran every test image through the application pipeline. RESULTS: Near-duplicates of training images accounted for 17.3% of test and 17.1% of validation images (lower bounds). Removing duplicated test images changed mean average precision (mAP)@0.5 by +0.001 (95% confidence interval [CI] -0.012 to +0.014). Only 22% of duplicated photographs had identical labels on both copies; exploratory analysis suggested memorization of training labels in orientations seen in training. A library update moved mAP@0.5:0.95 by -0.012 with identical predictions. The router rejected 23% of in-domain photographs and 51% of photographs with ulcers, so ulcer sensitivity per image was 0.36 despite the highest benchmark recall (0.91). A class-mapping defect, still live in a public demonstration in September 2026, gave the wrong name to 73% of findings. The histopathology classifier classified every image as positive; its label was not a diagnosis. CONCLUSION: Duplication compromised the benchmark's independence without detectably changing aggregate mAP; the defects that changed what was reported or displayed lay in the labels, evaluation software, and pipeline. Evaluations should verify partitions and labels, pin the library, and test deployed systems end to end.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Leakage-Aware and Reproducible Evaluation of Deep Learning Models for Multi-Class Oral Disease Image ClassificationComputers · 2026
- A large-scale assessment of modern deep learning architectures for multiclass oral histopathology: accuracy, efficiency, and statistical reliabilityFrontiers in Oncology · 2026
- Two-step pipeline for oral diseases detection and classification: a deep learning approachFrontiers in Oral Health · 2025
- Artificial Intelligence-Based Evaluation of Oral Potentially Malignant Disorders Using Photographic and Clinical Data: A Retrospective Exploratory Diagnostic Accuracy Study.Dentistry journal · 2026
- OraRefer: Segmentation-Guided Multi-Photograph Fusion for Oral Cancer Screening with Guaranteed Patient-Level SensitivityarXiv · 2026
- The Feasibility of One-Stage Instance Segmentation for Detecting Oral Potentially Malignant Disorders in White-Light Clinical Photographs: A Proof-of-Concept Study.Dentistry journal · 2026