On-Device ECG and Vital-Sign Prediction of 24-Hour Mortality and Unplanned ICU Admission in Emergency Department Patients: A Retrospective Evaluation of MEDI-AI.
Hyunjin Kyung, Dongbum Suh, Jin Hee Lee, Hyuksool Kwon
Department of Emergency Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea.
Key points
From the paper's conclusion- We evaluated MEDI-AI for 24 h mortality and unplanned intensive care unit (ICU) admission, with secondary diagnostic and triage assessments.
Abstract
Background/Objectives: Smartphone-based analysis of electrocardiograms (ECGs) and vital signs may support risk assessment without an integrated electronic health record feed. We evaluated MEDI-AI for 24 h mortality and unplanned intensive care unit (ICU) admission, with secondary diagnostic and triage assessments. Methods: This single-center retrospective evaluation included 2000 encounters from 2025 after supplementary development on 3000 encounters from 2024, with patient-level separation. Stored probabilities were assessed for area under the receiver-operating-characteristic curve (AUROC), calibration, and threshold performance. Post hoc exploratory NEWS2 and paired comparisons were performed; accepted inputs were also analyzed separately. Results: There were 189 deaths and 378 ICU admissions. Fusion AUROCs were 0.9994 and 0.9982; NEWS2 AUROCs were 0.8801 and 0.8131. Fusion-minus-vital-only AUROC differences were -0.000039 (95% CI, -0.000450 to 0.000366) and 0.002114 (0.000632 to 0.003920). Fusion calibration slopes were 5.62 and 6.09. STEMI and ACS sensitivities were 90.9% (58.7-99.8%) and 92.3% (74.9-99.1%). Triage critical-class recall was 24.9%. Input rejection occurred in 48 encounters; median recorded latency was 1235 ms. These stored-score estimates do not measure end-to-end deployable performance. Conclusions: Near-ceiling stored-score discrimination did not establish reliable absolute risks or a clinically usable workflow. Incomplete predictor-timing and model-development records limit reproducibility and assessment of bias. The evaluated triage configuration is unsuitable for clinical deployment, and the diagnostic analyses do not validate rule-out use. Independent external and prospective validation are required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating the Incremental Value of AI-Derived ECG Features Beyond Automated ECG Reports and Clinical Data for 30-Day Mortality: A MIMIC-IV Cohort StudymedRxiv · 2026
- Early radiology reports and ECG machine measurements do not measurably improve 30-day ICU mortality prediction from the first 6 h of the stay: a multimodal ablation with external validation of the structured EHR backbone.Frontiers in medical technology · 2026
- Real-Time Machine Learning Model to Predict Cardiac Arrest Within 12 Hours in Critically Ill Patients (DeepiCARS): A Confirmatory Trial and External Validation.Diagnostics (Basel, Switzerland) · 2026
- Multimodal Integration of Ambulatory ECG and Clinical Features for Sudden Cardiac Death and Pump Failure Death PredictionmedRxiv · 2026
- Predictive performance of vital sign–based prediction models for in-hospital cardiac arrest: a systematic review and meta-analysisBMC Cardiovascular Disorders · 2026
- Deep learning-based electrocardiography for sudden cardiac death risk prediction: a systematic review and meta-analysis of validation studiesEuropean Heart Journal · 2026