European Heart Journal

Deep learning-based electrocardiography for sudden cardiac death risk prediction: a systematic review and meta-analysis of validation studies

J Gohri, A J Jolly, S R Rao, A S Y Singh Yadav, S K Kalra, A M Maheshwari

Meta-analysis

Key points

From the paper's conclusion
  • ECG-AI models achieved AUROC 0.75–0.90 (median 0.85) for SCD prediction, significantly outperforming conventional ECG risk scores (AUROC 0.62, p<0.001) and guideline-directed ICD criteria.

Abstract

Background Sudden cardiac death (SCD) remains a leading cause of mortality in heart failure populations. Traditional ECG parameters and guideline criteria (LVEF <35%) identify only ~50% of high-risk patients. AI-derived ECG features may capture subclinical arrhythmic substrate. Evidence synthesis on ECG-AI SCD prediction needed. Methods MEDLINE, Embase, clinicaltrials.gov (2018–January 2026) searched for prospective cohort studies using machine learning/deep learning on ECG signals to predict SCD. Inclusion: N≥100, ≥1-year follow-up, reported discrimination metrics (AUC/C-statistic) for SCD outcomes, comparison to conventional ECG risk scores. Exclusion: case-control designs, synthetic ECG data. Primary outcome: AUC for SCD prediction. Random-effects meta-analysis; subgroup analyses by patient population (HF vs population-based), ECG-AI architecture (CNN, LSTM, Vision Transformer). Results Thirty-two studies (n=18,500 patients; 1,247 SCD events; median 2.8-year follow-up) included. ECG-AI models achieved AUROC 0.75–0.90 (median 0.85) for SCD prediction, significantly outperforming conventional ECG risk scores (AUROC 0.62, p<0.001) and guideline-directed ICD criteria. In HF subgroup: ECG-AI combined with clinical variables achieved AUROC 0.90 (95% CI 0.86–0.94) versus conventional criteria 0.68 (p<0.001). Three-year SCD discrimination improved from 28.7% (conventional high-risk) to 36.1% (ECG-AI high-risk) (p for trend <0.001). External validation: minimal performance degradation (median ΔC-statistic −0.04). Conclusions ECG-based AI models significantly enhance SCD risk identification with improved discrimination over guideline criteria (AUROC 0.85 vs 0.62). Integration into ICD implantation protocols may improve primary prevention strategies. Prospective randomized trials assessing ICD therapy guided by ECG-AI warranted.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers