Pilot Evaluation of Simplified HBV DNA Extraction-LAMP Workflows for Hepatitis B Molecular Testing in Resource-Limited Settings.
Nang Kham-Kjing, Warit Kongfu, Patcharaporn Matthanawut, Nachcharee Srisupattanakul, Sayamon Hongjaisee, Nicole Ngo-Giang-Huong, Woottichai Khamduang
Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai 50200, Thailand. · LUCENT International Collaboration, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai 50200, Thailand.
Key points
From the paper's conclusion- These findings require confirmation through formal analytical validation and larger, independent clinical studies before any clinical or implementation use can be considered.
Abstract
Background/Objectives: Access to hepatitis B virus (HBV) DNA testing remains limited in resource-limited settings. The main reasons for this are the high cost of molecular assays and the need for specialized infrastructure. This pilot study aimed to preliminarily develop and evaluate simple HBV DNA extraction methods combined with the colorimetric loop-mediated isothermal amplification (LAMP) technique. Methods: Three extraction methods were evaluated: (i) boiling-based, (ii) paper-based, and (iii) an adapted magnetic bead-based extraction method. Preliminary analytical performance was assessed using serially diluted HBV DNA-positive pooled plasma. Detection performance was evaluated using 40 clinical plasma specimens, including 35 HBV DNA-positive and 5 HBV DNA-negative samples, with real-time PCR as the reference standard. Results: The preliminary analytical detection level observed under the tested conditions was 105 IU/mL for the LAMP methods using boiling- or paper-based extraction, while it was 103 IU/mL with the adapted magnetic bead-based extraction-LAMP method. Evaluation using clinical specimens showed sensitivities of 43%, 54%, and 63%, respectively. Detection was dependent on viral load, with the highest detection observed among specimens with HBV DNA concentrations above 105 IU/mL. Conclusions: In this laboratory pilot, the workflows showed viral-load-dependent qualitative detection, with the adapted magnetic bead-based workflow yielding the highest observed detection rate. These findings require confirmation through formal analytical validation and larger, independent clinical studies before any clinical or implementation use can be considered.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Integrated recombinase-aided amplification–invader system: a closed-tube visual platform for hepatitis B virus detectionFrontiers in Cellular and Infection Microbiology · 2026
- Colorimetric polymerase spiral reaction (PSR) assay for the rapid detection of hepatitis B virusApplied Microbiology and Biotechnology · 2026
- Development and application of a real-time VPCR method for ultra-fast quantitative analysis and Visual Detection of HBV-DNA.Journal of clinical microbiology · 2026
- Electricity Free LAMP: A Protocol for Loop-Mediated Isothermal Amplification Using an Exothermic Chemical Reaction and Lyophilized ReagentsmedRxiv · 2026
- Evaluation of the Bosphore HBV Quantification Kit: Categorical and Quantitative Agreement with the Aptima HBV Quant Assay for HBV DNA Detection and Quantification.Microorganisms · 2026
- Next-Generation Sequencing Methods for Sensitive Hepatitis B Viral Genome Analysis: A European Study.Journal of medical virology · 2026