Urinary Red Blood Cell Distribution for Detection of Glomerular Hematuria: A Biopsy-Based Comparison with Direct Microscopy.
Nuttasith Larpparisuth, Paweena Kanogpotjananont, Kanit Reesukumal, Methawoot Khemmongkol, Gahwin Ruchikajorndech, Chanchira Janwijit, Peenida Skulratanasak
Division of Nephrology, Department of Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, 2 Prannok Road, Bangkok Noi, Bangkok 10700, Thailand. · Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, 2 Prannok Road, Bangkok Noi, Bangkok 10700, Thailand.
Key points
From the paper's conclusion- We evaluated the diagnostic performance of the UF-5000 analyzer for detecting glomerular hematuria (GH).
Abstract
Background: Differentiating glomerular from non-glomerular hematuria remains challenging. Automated urine analyzers with red blood cell (RBC) discrimination algorithms may provide an adjunct to conventional urine microscopy. We evaluated the diagnostic performance of the UF-5000 analyzer for detecting glomerular hematuria (GH). Methods: In this cross-sectional diagnostic study, patients with hematuria were classified into a GH group with biopsy-proven glomerular disease and a non-glomerular hematuria (NGH) group with non-glomerular causes confirmed by clinical, radiological, and/or pathological evaluation. Urine specimens were analyzed by a technician, a nephrology fellow, and the UF-5000 analyzer. Diagnostic performance was assessed using receiver operating characteristic (ROC) curve analysis and multivariable logistic regression. Results: A total of 201 patients were included, comprising 101 in the GH group and 100 in the NGH group. Urinary RBC distribution (URD) from UF-5000 analyzer was significantly higher in the GH group (66.3 ± 23.6 vs. 12.6 ± 19.8%; p < 0.0001). URD demonstrated the highest diagnostic performance among evaluated UF-5000 parameters, with an area under the ROC curve (AUC) of 0.946 (95% CI 0.914-0.979). The optimal Youden-derived URD cutoff ≥ 25% yielded 91.1% sensitivity and 89.0% specificity for identifying GH. Compared with microscopy, URD showed higher sensitivity than technician-performed microscopy (91.1% vs. 60.4%; p < 0.001) and similar performance to fellow-performed microscopy (91.1% vs. 83.2%; p = 0.237). Performance remained consistent across RBC count strata and major glomerular disease subtypes. Conclusions: URD was strongly associated with GH and demonstrated good discriminatory performance in this biopsy-based cohort. Automated urinary RBC analysis may complement conventional urine microscopy in hematuria evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deep Learning-Assisted Classification of Urinary Red Blood Cell Morphology for Glomerular Hematuria Screening: A Pilot Study.Journal of clinical laboratory analysis · 2026
- Recommendations for optimizing the use of dysmorphic red blood cell counts in the clinical laboratory.Advances in laboratory medicine · 2026
- B-001 Limitations of Urine Dipstick Testing and the Clinical Value of Creatinine-Normalized Quantitative Urinalysis in Urologic and Renal Disease DetectionClinical Chemistry · 2026
- Development of a deep learning model for glomerulus detection and segmentation in kidney histopathology imagesmedRxiv · 2026
- Urinary Uromodulin for Distinguishing Between Glomerulonephritis, Diabetic Kidney Disease, and Nephrosclerosis in a Biopsy-Proven Cohort.Diagnostics (Basel, Switzerland) · 2026