Key points
From the paper's conclusion- We aimed to characterize evidence on extended-wear infusion sets (>3 and ≤7 days) in people with type 1 diabetes (T1D), focusing on survival, safety, insulin delivery, glycemic outcomes, pharmacokinetic/pharmacodynamic parameters, and user experience.
Abstract
Background/Objectives: Infusion sets are essential for continuous subcutaneous insulin infusion. Conventional sets require replacement every 2–3 days, while recent research has focused on extending wear time to reduce treatment burden and support automated insulin delivery. We aimed to characterize evidence on extended-wear infusion sets (>3 and ≤7 days) in people with type 1 diabetes (T1D), focusing on survival, safety, insulin delivery, glycemic outcomes, pharmacokinetic/pharmacodynamic parameters, and user experience. Methods: A scoping review was conducted according to PRISMA-ScR. The protocol was registered in the Open Science Framework (OSF; DOI: 10.17605/OSF.IO/TNKJ5). MEDLINE/PubMed, Embase, Scopus, Web of Science Core Collection, and Cochrane CENTRAL were searched for studies published from 1 January 2020 to 4 September 2026. Eligible studies evaluated infusion sets worn for >3 days in people with T1D and reported extended-wear outcomes. Results: Of 229 records identified, 103 unique references were screened and 11 underwent full-text assessment. Ten publications met the inclusion criteria, representing 9 independent sources of evidence. In the largest studies, 7-day set survival ranged from 77.8% to 95%, depending on device and failure criteria. Some studies reported deterioration in glycemic or pharmacodynamic measures with prolonged wear, whereas others showed good tolerability and reduced burden from set changes. Conclusions: Extended-wear infusion sets can remain functional for 4–7 days in a substantial proportion of people with T1D, although performance may decline with increasing wear time. Evidence is limited by heterogeneity in devices and study designs, small samples, few direct comparisons, and difficulty isolating the infusion set effect from other technological components. Independent comparative studies are needed to establish safety, insulin delivery stability, and clinical benefit.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-World safety, patient-reported outcomes, and glycemic metrics with a 7-Day extended infusion set in adults with Type 1 diabetes using automated insulin delivery systems.Endocrine · 2026
- Impact of the use of Extended™ Wear Infusion sets on metabolic, ultrasound, and psychological outcomes in adults with type 1 diabetes using the Medtronic MiniMed 780G: a pilot randomized controlled trial.Endokrynologia Polska · 2026
- A nationwide 12‐month observatory of automated insulin delivery shows improved glucose control, sustained adoption, and reduced acute severe eventsDiabetes Obesity and Metabolism · 2025
- Advanced automated insulin delivery in inpatients receiving nutritional support: a single-center, open-label, randomised controlled trialDiabetes & Metabolism · 2026
- Artificial Pancreas and Closed-Loop Insulin Delivery: From Early Concepts to AI-Driven Diabetes Automation.Biosensors · 2026
- Automated Insulin Delivery Use Among Preschool-Age Children With Type 1 Diabetes: A T1D Exchange Multicenter AnalysisJournal of Diabetes Science and Technology · 2026