Plotting Residue Loci for Control Systems
Basil Mohammed Al-Hadithi, Munther N. Baker
Key points
From the paper's conclusion- This work presents a new graphical method for plotting the residue loci of linear time-invariant control systems as the gain varies.
Abstract
This work presents a new graphical method for plotting the residue loci of linear time-invariant control systems as the gain varies. While the classical root locus shows the trajectory of the closed-loop poles, it does not reveal the relative weight of each pole in the system response. The residues of the partial-fraction expansion provide precisely this information, since they determine the magnitude and phase of each modal component. The proposed residue-locus method establishes a set of construction rules analogous to those of Evans’ root locus, allowing the loci to be sketched and interpreted directly in the s-plane. The proposed construction rules are developed analytically and illustrated using representative low-order systems with different pole-zero configurations. For the second-order case with two open-loop poles and no zeros, the residues asymptotically satisfy A1≃−jK/2 and A2≃jK/2, with residue-locus asymptotes at 90∘ and 270∘. The residue-locus method, used together with the root-locus method, provides a unified analytical technique for control-system analysis and design, since it simultaneously describes how the location and the contribution of each closed-loop pole evolve with the gain. The method is intended as a complementary tool for studying transient response, modal dominance, and the relative activation of system modes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Damping Ratio and Convergence Rate Analysis for Inverter-Based Power Systems via Root LocusarXiv · 2026
- From Damping Ratios to Waveform Characteristics: A Residue-Based Mechanistic Analysis Framework for Hydropower Mechanical VariablesMachines · 2026
- A Generalized Order-Reduction Method for Transfer Function and Pole–Zero Analysis of Linear Analog CircuitsChips · 2026
- Effect of a fourth-order diffusion term on the robustness of the transfer function stability for hyperbolic systemsarXiv · 2026
- ANALISIS KOMPARATIF PENGENDALI P, PI, DAN PID MENGGUNAKAN METODE ULTIMATE GAIN ZIEGLER–NICHOLS PADA SISTEM SUSPENSI DUA DERAJAT KEBEBASANBarometer · 2026
- Exact Inversion of Relaxation from Rheometer Measurement DataarXiv · 2026