Long-Term Electrochemical Evaluation of Commercial Surface-Applied Corrosion Inhibitors for Chloride-Contaminated Reinforced Mortar
Lounis Djenaoucine, Andrés Bonilla, Amparo Moragues, Jaime C. Gálvez
Key points
From the paper's conclusion- This study evaluates the effectiveness of three commercial inhibitors (an alkoxysilane base, an alkylsilane mixture and an aqueous organo-mineral formulation) applied as surface rehabilitation treatments on mortar specimens contaminated with 2% Cl− by cement weight.
Abstract
The corrosion of reinforcing steel induced by chloride ingress is one of the main causes of premature deterioration in reinforced concrete structures. Among the available mitigation strategies, surface-applied corrosion inhibitors are attractive as a repair option because they are inexpensive and easy to apply to existing structures. However, comparative data on commercial surface-applied inhibitors of different chemical bases, tested on already-contaminated concrete under identical conditions, remain limited. This study evaluates the effectiveness of three commercial inhibitors (an alkoxysilane base, an alkylsilane mixture and an aqueous organo-mineral formulation) applied as surface rehabilitation treatments on mortar specimens contaminated with 2% Cl− by cement weight. The electrochemical behaviour of the embedded carbon steel was monitored over 370 days by means of linear polarisation resistance (LPR) and electrochemical impedance spectroscopy (EIS). The results showed that all three treatments reduced the corrosion rate relative to the untreated reference, with inhibition efficiencies of up to 90%, the alkoxysilane-based treatment giving the lowest corrosion rates. EIS revealed differences in the charge transfer resistance and pore solution response associated with each product. Nevertheless, none of the treatments achieved negligible corrosion conditions, indicating that surface-applied inhibitors mitigate but do not fully arrest chloride-induced corrosion under the conditions studied.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- On the effect of surfactants in the composition of the corrosion inhibitor for concrete reinforcement IFKhAN-78 during prolonged full immersion in 3% NaCl solution. Monitoring based on EIS resultsInternational Journal of Corrosion and Scale Inhibition · 2026
- Features of the action of the corrosion inhibitor IFKhAN-78 on pre-rusted reinforcement during long-term complete immersion of concrete in 3% NaCl solutionInternational Journal of Corrosion and Scale Inhibition · 2026
- EIS response and applicability assessment of equivalent circuit models for reinforcement corrosion in chloride-contaminated concreteWorld Journal of Engineering · 2026
- A Study on the Corrosion Resistance and Service Life Prediction of Water-Based Epoxy-Coated Reinforced Concrete in Harsh Environments.Materials (Basel, Switzerland) · 2026
- Sustainable Approaches to Corrosion Protection in Reinforced Concrete: A Critical Review of Green Inhibitors, Surface Treatments, Self-Healing Systems, Nanomaterials, Smart Coatings, and Life-Cycle-Based Design.Materials (Basel, Switzerland) · 2026
- Synergistic Mechanism of Nanoparticles and Corrosion Inhibitors in Electrochemical Repair: Pore Structure Refinement and Chloride Ion Removal of Reinforced Concrete.ACS omega · 2026