EIS response and applicability assessment of equivalent circuit models for reinforcement corrosion in chloride-contaminated concrete
Chao Wu, Bin Zhu, Juntao Kang, Hong Sheng Qiu, Jiahao Cui
Wuhan University of Technology
Key points
From the paper's conclusion- The FGS system (with internal inhibitor) showed the best performance, maintaining low corrosion current density even at 1.5% chloride, due to synergistic “matrix immobilization-interface inhibition.” Originality/value The establishment of a dynamic “material-age-mechanism” correlation model reveals chloride-induced corrosion transition pathways, while quantification of the metakaolin-inhibitor syn
Abstract
Purpose This study aims to systematically evaluate the corrosion mechanisms and the applicability of equivalent circuit models (ECMs) for steel reinforcement in five concrete systems with varying chloride contents and curing ages. By combining electrochemical impedance spectroscopy (EIS) and linear polarization resistance (LPR) techniques, it establishes a reliable correlation between LPR and EIS data and assesses the protective efficacy of mineral admixtures and corrosion inhibitors, providing a basis for durable concrete design in chloride-rich environments. Design/methodology/approach This study prepared five concrete systems (A, F, FG, FGS, FGX) with varying chloride contents (0–1.5% by binder mass) and curing ages (3, 7 and 28 days). Electrochemical tests were conducted using a three-electrode system and a CS2350M potentiostat. LPR measurements provided polarization resistance (Rp), while EIS data were fitted with ECMs to extract parameters like charge-transfer resistance (Rct). Data reliability was ensured through cross-validation between LPR and EIS results and linear regression analysis. Findings The study revealed a dynamic transition in corrosion mechanisms from charge-transfer control (3 days) to diffusion dominance (28 days) with increasing chloride concentration and age. ECMs evolved accordingly, achieving high accuracy (fitting error <10%). A strong linear correlation between Rp and Rct was observed under charge-transfer control but weakened under diffusion control. Hybrid systems (FG/FGS/FGX) demonstrated superior chloride resistance. The FGS system (with internal inhibitor) showed the best performance, maintaining low corrosion current density even at 1.5% chloride, due to synergistic “matrix immobilization-interface inhibition.” Originality/value The establishment of a dynamic “material-age-mechanism” correlation model reveals chloride-induced corrosion transition pathways, while quantification of the metakaolin-inhibitor synergy provides new insights into designing durable chloride-contaminated concrete.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long-Term Electrochemical Evaluation of Commercial Surface-Applied Corrosion Inhibitors for Chloride-Contaminated Reinforced MortarCorrosion and Materials Degradation · 2026
- Chloride Transport Resistance, Concrete Cover Performance, and Service-Life Assessment of Reinforced Concrete under Brazilian Durability Requirements.ACS omega · 2026
- Role of concrete design parameters in preventing corrosion-driven failures in reinforced concrete structuresJournal of Structural Integrity and Maintenance · 2025
- A Study on the Corrosion Resistance and Service Life Prediction of Water-Based Epoxy-Coated Reinforced Concrete in Harsh Environments.Materials (Basel, Switzerland) · 2026
- Evaluating the corrosion behaviour of FA-concrete using accelerated corrosion testingIOP Conference Series: Earth and Environmental Science · 2026
- Hierarchical ensemble machine learning for corrosion monitoring in reinforced concrete subjected to carbonation and cast-in-chloridesNondestructive Testing And Evaluation · 2026