Commercial Screen-Printed Electrodes as pH Voltammetric Sensors
Alex Campos, Luna Ipharraguerre, Clara Pérez-Ràfols, Núria Serrano, José Manuel Díaz-Cruz
Key points
From the paper's conclusion- Here, a critical assessment of commercial screen-printed electrodes (SPEs) as voltammetric pH sensors is presented, focusing on their electrochemical response, analytical response and practical limitations.
Abstract
The development of miniaturized pH sensors suitable for routine analytical implementation remains a central challenge in electrochemical analysis. Here, a critical assessment of commercial screen-printed electrodes (SPEs) as voltammetric pH sensors is presented, focusing on their electrochemical response, analytical response and practical limitations. Screen-printed carbon electrodes (SPCEs) and screen-printed gold electrodes (SPAuEs) were evaluated under minimal treatment. SPCEs exhibited no intrinsic pH sensitivity, and quinone-based electrochemically deposited layers showed insufficient stability for reliable measurements. In contrast, SPAuEs showed a well-defined pH-dependent response based on the reduction of electrochemically generated gold oxides. After HCl pretreatment, near- to super-Nernstian behaviour (up to 64 mV) was achieved over a wide pH range (2–12). SPAuEs demonstrated excellent inter-electrode reproducibility and good temporal stability, with variations not exceeding ±0.12 pH units. However, repeatability was affected by progressive surface modification, particularly at alkaline pH. This limitation was mitigated by introducing an intermediate regeneration step in acidic medium, which restores a consistent surface state. Accurate pH determinations were achieved across several buffer systems at 0.1 mol L−1 ionic strength, whereas lower ionic strengths and chloride ions significantly affected sensor performance. These results demonstrate that a pH-dependent gold oxide response alone does not guarantee reliable pH measurements. Instead, successful implementation of commercial SPAuEs requires appropriate surface conditioning, regeneration procedures and control of matrix effects. By defining these operational requirements and limitations, this work establishes a practical framework for the reliable use of commercial SPAuEs as voltammetric pH sensors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating Analytical Performance of Commercial Screen-Printed Electrodes for Point-of-Care Uric Acid Sensing: A Comparative StudyApplied Sciences · 2026
- Insights Into the Electrochemical Response of Commercial Carbon Screen‐Printed ElectrodesChemElectroChem · 2026
- Electrical and electrochemical pH sensing technologies: comparative mechanisms, performance, and applicationsJournal of Solid State Electrochemistry · 2026
- Electrochemical detection of organophosphorus pesticides using screen-printed electrodes: a systematic literature review.Analytical methods : advancing methods and applications · 2026
- Screen-printed carbon electrodes: processing, interface reconstruction, performance and sustainabilityJournal of Electrochemical Science and Engineering · 2026
- All-3D Printed Microelectrodes.Analytical chemistry · 2026