Cancers

Performance of ASAP, LG2m, and GP73 for HCC Detection in Patients with Cirrhosis.

Mohammad Jarrah, Mohammed Al-Hasan, Mariadelcarmen Yanez, Maria V Yow, Eunice Amador, Diya Kar, Fouzia Ahmed, Nicole E Rich,

Department of Internal Medicine, UT Southwestern Medical Center, Dallas, TX 75390, USA. · Abbott Diagnostics, Abbott Park, IL 60064, USA.

Observational · n=294

Key points

From the paper's conclusion
  • These findings suggest a need for optimized cutoffs prior to implementation in clinical practice.

Abstract

Background: The sensitivity of ultrasound plus alpha-fetoprotein (AFP) for early-stage hepatocellular carcinoma (HCC) detection remains suboptimal, prompting interest in blood-based biomarkers as an alternative strategy. The ASAP [age, sex, AFP, PIVKA-II] score has promising performance, although validation in contemporary Western populations is needed. Methods: We conducted a case-control study in which the cases were patients with HCC and the controls had cirrhosis without HCC. AFP, PIVKA-II, LG2m, and GP73 were measured using the Abbott Alinity platform, and ASAP scores were calculated. Sensitivity and specificity for early-stage HCC (BCLC stage 0/A) were compared between ASAP and ultrasound plus AFP using McNemar's chi-square test. Results: Among 294 patients (median age of 61 years, 67.7% men), 50.7% had HCC (69.1% BCLC 0/A), and 49.3% had cirrhosis. The performance of individual biomarkers for early-stage HCC was moderate to poor (AUROC: AFP 0.71, PIVKA-II 0.73, LG2m 0.51, and GP73 0.53). ASAP, at a cutoff of ≥0.526, demonstrated a sensitivity of 88.3% for early-stage HCC, with specificity of 54.5%. Sensitivity was higher in men and viremic HCV, whereas specificity was higher in younger individuals, women, and Child-Pugh A cirrhosis. In subgroup analysis (n = 178), ASAP had comparable sensitivity to ultrasound plus AFP (85.5% vs. 90.3%; p = 0.51) but lower specificity (53.4% vs. 93.1%; p < 0.001). Using the Youden-optimized cutoff (≥0.804) improved specificity to 83.4% while maintaining a sensitivity of 68.0% for early-stage HCC. Conclusions: ASAP demonstrated high sensitivity for early-stage HCC detection but low specificity. These findings suggest a need for optimized cutoffs prior to implementation in clinical practice.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Performance of ASAP, LG2m, and GP73 for HCC Detection in Patients with Cirrhosis — Science Skim