A pH-Sensitive Sprayable Fluorescent Probe Enables Accurate Visualization of Thyroid Cancer Margins for Fluorescence-Guided Surgery in Orthotopic Mouse Models
Hyungju Kwon, Javier Bravo, Ting-Chun Kuo, Blackberrie Eddins, Siamak Amirfakhri, Jasmin Zaker, Keita Kobayashi, Shinya Yokomizo,
Ewha Womans University · University of San Diego
Key points
From the paper's conclusion- This study aimed to demonstrate that a sprayable pH-sensitive near-infrared fluorescent probe (PH10) could specifically and robustly label thyroid tumors in orthotopic mouse models.
Abstract
Positive surgical margins (PSMs) are a major predictor of recurrence in thyroid cancer; however, their intraoperative detection remains challenging, particularly for microscopic PSMs. This study aimed to demonstrate that a sprayable pH-sensitive near-infrared fluorescent probe (PH10) could specifically and robustly label thyroid tumors in orthotopic mouse models. The pH sensitivity, cytotoxicity, and cellular uptake mechanisms of PH10 were evaluated in papillary thyroid carcinoma (K1) and anaplastic thyroid carcinoma (8505C) cell lines in vitro. Orthotopic thyroid cancer mouse models were then established using both K1 and 8505C cells. In vivo fluorescence following topical spraying of PH10 was quantified after sequential washes to assess tumor-to-background ratios. Fluorescence-guided surgery (FGS) was performed to determine whether PH10 could facilitate complete resection of orthotopically grown thyroid tumors. Complete resection was validated by hematoxylin and eosin histology. PH10 demonstrated low cytotoxicity at clinically relevant concentrations in vitro and showed selective uptake into thyroid cancer cells, predominantly via organic anion transporting polypeptide-mediated transport. Topical spraying of PH10 in orthotopic thyroid cancer mouse models established from K1 and 8505C cell lines generated strong tumor-specific fluorescence. Tumor-to-background ratios were significantly higher than background and remained distinguishable after multiple washes. In both models, PH10 enabled visualization of macroscopic residual tumors and detection of microscopic PSMs, with fluorescence patterns closely corresponding to histologic findings. FGS enabled complete tumor resection, as confirmed by fluorescence and histology. In conclusion, topical application of PH10 provides rapid, tumor-specific fluorescence suitable for identifying PSMs and facilitating complete tumor resection by FGS in thyroid cancer.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rapid Ex Vivo Visualization of Laryngeal Tumors Using a Sprayable pH-Activatable Fluorophore.Molecular diagnosis & therapy · 2026
- Advances in Optical and Fluorescence Imaging for Surgical Management of Thyroid Cancer.Cancers · 2026
- Probe-Based Near-Infrared Autofluorescence for Parathyroid Identification During Thyroid Surgery: Clinical Outcomes, Surgeon Confidence, and Autofluorescence Thresholds.Head & neck · 2026
- Small-Molecule Far-Red Fluorescent Spray-on Probes Targeting Prostatic Acid Phosphatase for Fluorescence-Guided SurgeryBioconjugate Chemistry · 2026
- Decoupling functional morbidity from oncologic burden through fluorescence-guided thyroid cancer surgery.Updates in surgery · 2026
- Preliminary Application of TROP2-Targeted Peptide Screening for Real-Time Intraoperative Navigation in Pancreatic Cancer.Chemical & biomedical imaging · 2026