Influence of Partial and Asymmetric Strengthening of Timber Floors on the Seismic and Gravity-Load Response of Historic Unreinforced Masonry Buildings
Ivan Volarić, Dean Čizmar, Mislav Stepinac, Šime Serdarević
Key points
From the paper's conclusion- This study compares fourteen three-dimensional equivalent-frame models of two Zagreb URM building types through 336 nonlinear static analyses using the N2 method.
Abstract
Historic unreinforced masonry (URM) buildings with flexible timber floors are seismically vulnerable because diaphragms deform in plane and wall–floor connections are often inadequate. In practice, strengthening may be limited to the attic or an asymmetric part of a storey. This study compares fourteen three-dimensional equivalent-frame models of two Zagreb URM building types through 336 nonlinear static analyses using the N2 method. A cross-laid 2 × 30 mm glued-laminated timber panel and an 80 mm timber–concrete composite slab were modelled at the attic only, at the attic and half of an intermediate floor, or at all levels above the basement. Separately, 144 joist cross-section/span combinations were assessed for ultimate and serviceability limit states under vertical actions. For TYPE A, attic-only strengthening increased the X-direction seismic resistance index (αSD) by 22.2% but reduced its Y-direction value by 27.3%. For TYPE B, comprehensive strengthening increased the minimum index by 40% (timber) and 32% (composite). Both vertical limit states were satisfied by 47.9%, 68.8%, and 84.7% of combinations for original, timber-strengthened, and composite-strengthened joists, respectively. For the analysed models, and assuming effective wall–floor connections, intervention continuity and distribution governed the global response more strongly than nominal diaphragm stiffness, while the resistance of the unstrengthened walls remained critical.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Seismic behavior degradation of timber frame considering joint looseness-induced tilt damage in multi-story historic timber structureStructures · 2026
- Innovative Methods for Retrofitting Timber Structures for Seismic Safety: The Case of TekirdagBuildings · 2026
- Modelling of FRP-Strengthened Masonry Buildings with Equivalent Frame ModelsBuildings · 2026
- Numerical analysis of the in-plane behavior of unreinforced masonry walls with flangesFrontiers in Built Environment · 2026