Numerical analysis of the in-plane behavior of unreinforced masonry walls with flanges
Babak Enami Alamdari, Amirhossein Ghezelbash
Key points
From the paper's conclusion- The results show that Flange effects manifest as early as when flanges with 10% of the length of the main panel are considered, by changing flexural failure mechanisms to shear-dominated ones, reducing crushing and diagonal cracking, and increasing frictional resistance.
Abstract
This paper presents a comprehensive numerical study on the effects of flanges on the in-plane (IP) response of non-framed unreinforced masonry (URM) walls, along with new predictive equations for the IP strength of flanged URM walls. Although the global response of URM buildings is defined by interactions between walls, including damage transfer and the contribution of each wall to the performance of the wall perpendicular to it, collectively referred to as Flange effects, most experimental and numerical studies on URM treat walls as isolated components and do not account for these effects. Moreover, current design and assessment guidelines generally overlook Flange effects. To contribute to addressing this knowledge gap, this research conducts a parametric analysis of the IP monotonic behavior of URM walls with different combinations of geometries, flange lengths, overburden, and boundary conditions. The walls are simulated unit-by-unit using a block-based finite-element modeling approach, which uses nonlinear expanded blocks and shear-frictional zero-thickness joints, and employs an explicit solution procedure. The results of the 450 flanged wall and 45 non-flanged wall analyses are then used to propose simple regression-based predictive equations for the IP strength of the walls, particularly by proposing modifications to the classic equations used in ASCE 41. The results show that Flange effects manifest as early as when flanges with 10% of the length of the main panel are considered, by changing flexural failure mechanisms to shear-dominated ones, reducing crushing and diagonal cracking, and increasing frictional resistance. Flanges are shown in this study to increase strength, stiffness, and ductility by 1%–204%, 16%–192%, and 0%–185%, respectively, depending on boundary conditions, height-to-length aspect ratio of the main panels, and pre-compression. Each wall property has a different importance for Flange effects, depending on which IP performance parameter is studied. Finally, the proposed equations offer satisfactory accuracy in predicting the IP failure mechanism and strength of real flanged walls, while being simpler and more accessible than previous analytical developments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Three‐Dimensional Macroelement Formulation for the Biaxial Response of Masonry WallsEarthquake Engineering & Structural Dynamics · 2026
- Simplified Macro-Model for Non-Interactive Masonry Infill WallsJournal of Earthquake Engineering · 2026
- Numerical modeling of the out-of-plane dynamic response of masonry gable walls via a high-fidelity block-based finite element modeling approach - part II: post-diction and application to other structural configurations.Bulletin of earthquake engineering · 2026
- Modelling of FRP-Strengthened Masonry Buildings with Equivalent Frame ModelsBuildings · 2026
- Explicit Method for the Simulation of the Out-of-Plane Collapse of Unreinforced Masonry Walls: Influence of Hourglass Control, Damping, and Element FormulationBuildings · 2026
- Review of the influence of the interaction between in-plane and out-of-plane behaviors on the seismic response of framed unreinforced masonry wallsStructures · 2025