  • This study compares three representations of a 28-story reinforced-concrete building in Bangkok: load-and-mass-only walls (M1), stiffness-engaged exterior precast façade panels (M2), and M2 with a hypothetical interior-precast configuration (M3).

Abstract

Architectural wall panels excluded from a building’s designated seismic-force-resisting system may nevertheless alter lateral response through deformation compatibility. This study compares three representations of a 28-story reinforced-concrete building in Bangkok: load-and-mass-only walls (M1), stiffness-engaged exterior precast façade panels (M2), and M2 with a hypothetical interior-precast configuration (M3). Modal, code-based equivalent-lateral-force and response-spectrum, event-specific nonlinear response-history, and nonlinear pushover analyses were evaluated. Supplementary linear tests examined wall and slab flexural stiffness and in-plane diaphragm flexibility. Switching from rigid to semi-rigid diaphragms increased maximum equivalent-lateral-force X-direction interstory drift by 2.38%, 35.99%, and 37.98% for M1–M3, respectively. At matched roof displacements, common-force-distribution pushover analyses changed directional lateral base resistance by −9.58% to +11.44% relative to original modal-force analyses; loading histories and numerical controls were not completely matched. The originally derived building-specific response-modification indicators were 1.996/2.884, 9.020/4.956, and 3.092/4.717 (M1–M3, X/Y) but reflect nonuniform numerical terminal-state definitions, not independently verified global-collapse capacities. These results identify modeling-dependent trends and bound the interpretation of panel engagement and derived strength–deformation indicators.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers