Sensitivity of Seismic Response and a Building-Specific Response-Modification Indicator to Precast Wall-Panel Engagement in a 28-Story Reinforced-Concrete Building in Bangkok
Singhawapee Rattanavijit, Arthit Petchsasithon
Key points
From the paper's conclusion- This study compares three representations of a 28-story reinforced-concrete building in Bangkok: load-and-mass-only walls (M1), stiffness-engaged exterior precast façade panels (M2), and M2 with a hypothetical interior-precast configuration (M3).
Abstract
Architectural wall panels excluded from a building’s designated seismic-force-resisting system may nevertheless alter lateral response through deformation compatibility. This study compares three representations of a 28-story reinforced-concrete building in Bangkok: load-and-mass-only walls (M1), stiffness-engaged exterior precast façade panels (M2), and M2 with a hypothetical interior-precast configuration (M3). Modal, code-based equivalent-lateral-force and response-spectrum, event-specific nonlinear response-history, and nonlinear pushover analyses were evaluated. Supplementary linear tests examined wall and slab flexural stiffness and in-plane diaphragm flexibility. Switching from rigid to semi-rigid diaphragms increased maximum equivalent-lateral-force X-direction interstory drift by 2.38%, 35.99%, and 37.98% for M1–M3, respectively. At matched roof displacements, common-force-distribution pushover analyses changed directional lateral base resistance by −9.58% to +11.44% relative to original modal-force analyses; loading histories and numerical controls were not completely matched. The originally derived building-specific response-modification indicators were 1.996/2.884, 9.020/4.956, and 3.092/4.717 (M1–M3, X/Y) but reflect nonuniform numerical terminal-state definitions, not independently verified global-collapse capacities. These results identify modeling-dependent trends and bound the interpretation of panel engagement and derived strength–deformation indicators.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of Shear Wall Placement Variations on Seismic Response of Reinforced Concrete Dual-System BuildingsJURNAL TEKNIK SIPIL CENDEKIA (JTSC) · 2026
- The Effects of Infill Wall Configuration and Building Height on the Seismic Fragility of Reinforced Concrete BuildingsBuildings · 2026
- A Three‐Parameter Continuum Timoshenko Beam Framework for Evaluating Higher‐Mode Effects in High‐Rise Buildings With Rotational and Translational Base FlexibilityEarthquake Engineering & Structural Dynamics · 2026
- Influence of axial compression ratio on seismic performance of modular prefabricated composite shear walls with four-sided connectionsJournal of Physics: Conference Series · 2026
- Structural Behavior of Prefabricated Concrete Wall Panels and Their Connections: A State-of-the-Art and Practice ReviewBuildings · 2026
- Experimental–numerical Framework for Intelligent Finite Element Model Updating of a Full-scale Laboratory Footbridge StructureJournal of Vibration Engineering & Technologies · 2026