Buildings

The Effects of Infill Wall Configuration and Building Height on the Seismic Fragility of Reinforced Concrete Buildings

Gürkan Tam, Burak Yön, Mehmet Emin Öncü

Key points

From the paper's conclusion
  • The analytical results reveal that both building height and infill wall distribution play a decisive role in the seismic performance of RC frame structures.

Abstract

This study evaluates the seismic response of reinforced concrete (RC) frame buildings by examining the combined influence of infill wall arrangement and building height. For numerical study three structural configurations were considered: Model-1, an RC frame without infill walls; Model-2, an open-ground-storey system with infill walls omitted at the ground floor and provided at the upper stories; and Model-3, an RC frame with infill walls throughout the building height. Each configuration was developed as 3-, 6-, 9-, and 12-storey buildings, resulting in a total of twelve analytical models. For all models, the storey height was fixed at 3.0 m, while the concrete compressive strength and reinforcing steel yield strength were taken as 25 MPa and 420 MPa, respectively. To maintain structural design requirements for increasing building heights, the dimensions of the primary structural members were adjusted accordingly. The nonlinear response of the buildings was represented using a lumped plastic hinge approach. The numerical investigation was performed using eleven recorded earthquake ground motions, each of which was scaled from 0.1 g to 1.0 g in increments of 0.1 g. Because the selected buildings possess symmetric plan layouts, nonlinear incremental dynamic analyses (IDAs) were conducted by simultaneously applying the earthquake records in both the X and Y directions. Accordingly, 110 nonlinear dynamic analyses were carried out for each structural model, resulting in a total of 1320 analyses. In addition, nonlinear static pushover analyses were performed to establish the capacity curves of all building models. The analytical results reveal that both building height and infill wall distribution play a decisive role in the seismic performance of RC frame structures. The inclusion of infill walls substantially increases the initial lateral stiffness and lateral load-resisting capacity of the buildings. However, the absence of infill walls at the ground storey leads to a concentration of inter-storey drift demands within the lower stories, thereby increasing the likelihood of severe structural damage. Moreover, the contribution of infill walls becomes progressively more significant as the number of stories increases, resulting in marked differences in seismic performance and fragility characteristics among the investigated structural configurations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers