Shake-Table Response of a Three-Level Cold-Formed Steel Storage Rack Under Harmonic Excitation: Peak Accelerations, Interlevel Displacements, and Amplitude-Dependent Frequency
George Taranu, Viorel Ungureanu, Zsolt Nagy
Key points
From the paper's conclusion- These findings support reporting acceleration demand with its processing definition and frequency with its response amplitude.
Abstract
Broadband acceleration peaks can obscure how a storage rack responds at the excitation frequency. This study examines that distinction through shake-table and free-vibration tests on a full-scale, three-level cold-formed steel rack with restrained added mass at its middle level. Six incremental sine-beat runs at nominal 1 Hz were analysed alongside pre-run and post-run impact records. The synchronous top-to-table amplitude ratio remained nearly constant at 2.89–3.04, while the broadband peak ratio increased from 3.43 in the first run to 5.82 in the last. The latter was sensitive to processing bandwidth. Interlevel displacement demand concentrated in the lower two intervals. Free-vibration frequency decreased with response amplitude, and five pre-run impacts reproduced this dependence. A mechanical discussion distinguishes possible geometric and connection-related contributions without assigning a uniquely identified cause. The post-run frequency difference does not establish permanent stiffness degradation. A systematic discrepancy between the acceleration and displacement acquisition chains limits independent validation of absolute laser displacements. These findings support reporting acceleration demand with its processing definition and frequency with its response amplitude.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimental and Numerical Investigation on the Behavior of a One‐Story CFS‐Framed Building Under Shaking Table ExcitationEarthquake Engineering and Resilience · 2026
- Spectral Characterization of Digital Ground Displacement Records in the Low 0.03–0.30 Hz Range: Low Predominant Frequency Corroboration and Seismic Structural Resonance ApplicationBuildings · 2026
- An Examination of the Reasons for, and Variability of, the Differences Between Response Spectra and Pseudo Response SpectraEarthquake Spectra · 2026
- Base isolationMendeley Data · 2026
- Long‐Term Earthquake Response in a Midrise Reinforced Concrete Building: Insights From Hybrid Seismic MonitoringEarthquake Spectra · 2026
- Dynamic soil testing and assessment of the impact of vibrations from the RC/TS device using motion magnification technologyStudia Geotechnica et Mechanica · 2026