Experimental and Numerical Investigation on the Behavior of a One‐Story CFS‐Framed Building Under Shaking Table Excitation
Mohammad Rahimibala, Fayaz R. Rofooei
Key points
From the paper's conclusion- The developed model demonstrates excellent agreement with experimental results, showing: (1) close correlation in natural period between the numerical model and physical structure, and (2) nearly identical peak story absolute acceleration responses.
Abstract
The behavior of Cold‐Framed Steel (CFS) frames under earthquake loads must be examined before CFS building systems can be integrated fully into the construction market. Over the past 20 years, studies have focused on the subsystem level, while system‐level performance has been less studied. This paper aims to bridge the gap between subsystem and system‐level performance. In this regard, a full‐scale shake‐table test is conducted using results from subsystem‐level tests to provide experimental insight into the behavior of real 3D CFS‐framed structures under seismic excitation. The CFS‐framed building is designed in accordance with the Iranian Cold‐Formed Light Steel Structures Design and Construction Code. The building's structural system comprises CFS, CFS‐framed shear walls with two‐sided and one‐sided sheathings, and a k‐brace for lateral force‐resisting shear walls. The CFS test structure features a rectangular floor plan measuring 2.9 m × 3.10 m, with a uniform story height of 2.4 m throughout all levels. Using signal‐processing techniques, the frequency response function of the CFS specimen is determined to identify its natural frequencies and damping ratios. The structure is subjected to ground motion tests on the shake‐table. Then, simplified numerical models are developed in OpenSees. Nonlinear time‐history analyses were performed on finite element models of the CFS building, with results systematically compared with shake‐table test data to validate the proposed simplified modeling approach. The developed model demonstrates excellent agreement with experimental results, showing: (1) close correlation in natural period between the numerical model and physical structure, and (2) nearly identical peak story absolute acceleration responses.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fragility Analysis of Cold-Formed Steel Structures Under Combined Wind and Earthquake HazardsBuildings · 2026
- Shake Table and Numerical Evaluation on the Seismic Performance of Elastic‐boundary Ceiling SystemsEarthquake Engineering & Structural Dynamics · 2026
- Flexural capacity and failure characteristics of built-up cold-formed steel beamsJournal of Engineering and Applied Science · 2026
- Numerical Simulations of 5‐Story Building Using Wood Light‐Frame Shear Walls and Post‐Tensioned Cross‐Laminated Timber Rocking Wall Dual SystemsEarthquake Engineering & Structural Dynamics · 2026
- Development and Application of a Two-Dimensional Self-Tapping Screw Connection Element Incorporating Contact History and Slip Evolution for Steel-Sheathed Cold-Formed Steel WallsBuildings · 2026
- The Effects of Infill Wall Configuration and Building Height on the Seismic Fragility of Reinforced Concrete BuildingsBuildings · 2026